PANEL COMPATIBILITY
The UNIMPPT uses Buck Synchrone technology. It lowers the panel voltage into a lower value voltage for
the battery. The regulator turns on when the PV voltage (Voc) exceeds the battery voltage by more than
+5V.
The regulator will turn off when the PV voltage (Voc) is less than Vbat +1V.
Check before connecting
The maximum PV voltage in open circuit of the panel(s) in series (Voc) may not exceed 60V
for the UNIMPPT 60/15.24
!
A higher voltage can damage the regulator.
This damage is not covered by the warranty.
It's charging intensity is a 15A 24V charge
!
Panel power
The peak power of the solar panels is given according to normalized test conditions(STC): 1000W/m²
solar radiation, cell temperature at 25°C.
In standard usage, the normal operating cell temperature (NOCT) is 45°C +/- 2% and solar radiation is
800W/m². A 150W panel produces, as shown below, in reality 100W. The UNIMPPT 30.10/12S, which
can convert output upto 150W, is perfectly suited for panel power up to 150W* with a 12V battery.
*Voltage Uocv of panel(s) = 60V max.
Panel power delivered at real maximum solar radiation compared to theoretical solar radiation STC
1000W/m²
8A
7A
800W/m²
6A
5A
4A
500W/m²
3A
250W/m²
2A
1A
0A
10V
Maximum sunshine in France produces 25% less power compared to normative sunshine.
(normative at 25°C)
15V
20V
www.uniteck.fr
Lille
Marseille
25V
WINTER
SUMMER
200W/m²
700W/m²
500W/m²
850W/m²
EN
27/59