 The surface of the device and the interior of the
container should be regularly cleaned with a
moist cloth.
ATTENTION
Clogged ventilation slits
Risk of damage to the suction motor.
Keep the device and ventilation slits
clean to ensure good and safe working
conditions.
 Should the vacuum cleaner fail despite our thor-
ough manufacturing and testing procedures, re-
pairs are to be performed by a Würth Master
Service.
You can contact Würth Master Service free of
charge in Germany via 0800-WMASTER
(0800-9 62 78 37) or in Austria via 0800-20
30 13.
 For all queries and spare part orders, always
state the item number according to the type
plate of the vacuum cleaner.
Replacing the flat fold filter
1. Open the filter cover.
2. Remove the filter frame.
Figure K
3. Remove the flat fold filter.
4. Dispose of the used flat fold filter in accordance
with statutory regulations.
5. Remove any dirt deposits from the clean air side.
6. Clean the filter frame and the supporting sur-
face of the filter frame with a damp cloth.
7. Fit the new flat fold filter. During insertion, en-
sure that the flat fold filter is flush on all sides.
8. Insert the filter frame.
9. Close the filter cover until it audibly latches into
place.
Changing the fleece filter bag
1. Close the suction connection, see wet vacuum
cleaning.
Figure C
2. Unlock and remove the suction head.
3. Pull the fleece filter bag out to the rear.
Figure D
4. Fold in the lock latch and seal the fleece filter
bag tight.
5. Dispose of the used fleece filter bag in accord-
ance with statutory regulations.
6. Fit the new fleece filter bag.
7. Fit and lock the suction head.

Changing the dust bag

1. Close the suction connection, see wet vacuum
cleaning.
Figure C
2. Unlock and remove the suction head.
3. Fold up the dust bag.
Figure E
4. Pull the dust bag opening towards the rear over
the suction hose port.
5. Seal the dust bag tightly underneath the open-
ing using cable ties.
6. Remove the dust bag.
7. Dispose of the dust bag in accordance with
statutory regulations.
8. Fit the new dust bag.
9. Pull the dust bag over the container.
10.Fit and lock the suction head.
Cleaning/replacing the cooling air
1. Allow the device to cool down.
2. Unlock the cooling air flaps with a screwdriver
and fold them out.
Figure L
3. Clean (vacuum, wash) or replace the cooling
air filter.
4. Fold the cooling air flaps in and latch it into
place.

Cleaning the electrodes

1. Unlock and remove the suction head.
2. Clean the electrodes with a brush.
3. Fit and lock the suction head.
English
filter
23