Apex Cleco mPro400GCD-P Manual De Usuario página 11

Ocultar thumbs Ver también para Cleco mPro400GCD-P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

X9, X10 – Input/Output
The required signal circuits are connected to these input/
output connectors. The signal groups are not galvanically
connected to the power supply; galvanic isolation is
required.
16 digital inputs/outputs, optically isolated for 24 V
level/0.5 A
8 inputs/8 outputs/2 +24 VDC/2 GND
Output current: 500 mA per output, 2000 mA total
Note
A single device must not require a current of
more than 500 mA. The current monitor
switches off the output in the event of an
overcurrent.
Connectors – Internal power supply
Signal X9
Pin
I/O
12
Off
11
On
10
Output
9
Output
8
Output
7
Output
6
Input
5
Input
4
Input
3
Input
2
On
1
Off
Inputs
Internal 24 V power supply for the controller.
Pin 11 and 23 (common GND) serve as a "return line"
for the outputs.
Pin 11 and 23 must be connected to Pin 12 or 24 with
jumpers.
Apex Tool Group
Name
GND Int.
GND I/O
O3
O2
O1
O0 (linking OK), e.g.
I3 (tool start), e.g.
I2
I1
I0
+24 V O
+24 V Int.
Outputs
P2300HW | 2019-03
2x12 pin Phoenix MCD 0.5/24-G1-2.5
Order No. S981211
X9
Mating connector
Phoenix FK-MC 0.5/12-STZ3-2.5
Order No. S981211
Signal X10
Pin
I/O
Name
24
Off
GND Int.
23
On
GND I/O
22
Output
O7
21
Output
O6
20
Output
O5
19
Output
O4
18
Input
I7
17
Input
I6
16
Input
I5
15
Input
I4
14
On
+24 V O
13
Off
+24 V Int.
Internal 24 V power supply for the controller
Pin 2 and 14 (common output) are the voltage source
for the inputs.
Pin 2 and 14 must be connected to Pin 1 or 13.
1
EN
X10
11

Publicidad

Tabla de contenido
loading

Tabla de contenido