Troubleshooting - Urrea 2493 Manual De Usuario

Pluma hidráulica plegable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

E N G L I S H
systems used in these devices staff.
Periodically clean and grease the axles
and moving parts of the Shop Crane
(F), which must always be clean and
protected from aggressive environments.
Only original spare parts should be used.
Before each use, check for bent, broken,
cracked or loose parts. Remove the Shop
Crane from service if you suspect it has
been subjected to abnormal loads or has
suffered a blow, until you have fixed the
problem.
The oil level needs to be checked or
continuously filled, remove the hydraulic
unit and the piston fully retracted,
remove the filler plug hole and empty
the contents into a bowl. With hydraulic
horizontally, proceed to introduce the
necessary volume. Avoid getting dirt
with the new oil.
IMPORTANT: An excess of oil on the
required
volume
operation of the Shop Crane. Use
hydraulic oil (F), HL or HM type, with
an ISO viscosity grade Maximum 30 cSt
kinematic at 40, or a viscosity of 3 Engler
at 50° C .
DO NOT USE BRAKE FLUID.
OPERATING INSTRUCTIONS
It is possible that air has got into the
hydraulic system, causing poor lifting
performance, purge any air from the
system by fully opening release valve
(turn handle counterclockwise), then
while holding the jib down, operate
8
can
prevent
the
pump handle rapidly several times.
To raise load
• Close
release
overtighten.
To lower load
• Open release valve by turning
handle very slowly, the speed of
lowering the load is controlled by
how much you turn the handle.
When the Shop Crane is not running, it
should be fully retracted in the lowest
position to minimize oxidation of the
piston.
We recommend applying an antioxidant
in both the main piston and in pump.
Keep the Shop Crane in a clean, dry
place.
TROUBLE SHOOTING
PROBLEM
Will not hold load
CAUSE
SOLUTION
• Lower lifting jib. Close the release
valve and remove oil filler plug.
• Place one foot on the leg and pull
up the lifting jib to its full height
Dirt on valve
by hand.
seats.
• Open the release valve to lower the
lifting jib.
• Worn seals.
PROBLEM
Will not lift load
CAUSE
SOLUTION
• Open the release valve and remove
oil filler plug.
Air block
• Pump handle a couple of full
strokes and close the release valve.
PROBLEM
Pump will not lift to its full height
CAUSE
SOLUTION
The reservoir
• Check the oil level.
could be over
• Remove the filler plug.
filled
PROBLEM
Will not lower completely
CAUSE
SOLUTION
Air block
• Release air from hydraulic pump by
removing filler plug.
Unit requires
• Oil external moving parts.
lubrication
valve
do