HOW TO PREPARE THE MACHINE
FOR OPERATION
How to program battery charger (WET or AGM batter-
ies):
According to the type of batteries (WET or AGM), set the
machine and electronic board of the battery charger as
follows:
Charger Setting
1.
Turn the key switch "ON" (see figure 5A, item A) and
in the very first seconds of machine operation pay
attention to the following:
• If the green warning light (item B) is flashing, the
charger is set to AGM.
• If the yellow warning light (item C) is flashing, the
charger is set to GEL EXIDE.
• If the red warning light (item D) is flashing, the
charger is set to WET.
2.
If the setting is to be changed, perform the following
procedure:
a. Turn the key switch "OFF".
b. Press and hold the buttons (items E and F) at the
same time, then turn the key switch (item A) "ON".
c. Continue to hold the buttons (items E and F) until
the battery meter LED light turns "ON" and "OFF"
and then release both buttons.
d. Within 3 seconds, toggle the button (item F) to
advance the green bar (item G) to the desired
charger setting (see green bar position for charger
settings below):
Green bar setting (item G)
• 1st green bar - WET @ 25 amps, 250 & 330 ah
batteries (4 RED blinks).
• 2nd green bar - GEL/AGM @ 25 amps, 260 &
312 AGM (4 GREEN blinks).
• 3rd green bar - GEL EXIDE @ 25 amps (4
YELLOW blinks).
• 4th green bar - WET @ 15 amps (2 RED blinks).
• 5th green bar - GEL/AGM @ 15 amps (2 GREEN
blinks).
• 6th green bar - GEL EXIDE @ 15 amps (2
YELLOW blinks).
e. Once proper battery charger profile is selected, wait
until battery LED light quits flashing and stays on
before turning key switch "OFF".
f. Repeat step 1 to verify that proper charger profile
was programmed for battery type (WET or GEL).
NOTE: