• Before installing the automatic system read the instructions hereunder carefully.
• It is strictly forbidden to use the product BOB3024 FC for applications other than indicated in this instruction hand-
book.
• Show the user how to use the automation system.
• Give the user the part of the leaflet which contains the instructions for users.
• All Benincá products are covered by an insurance policy for any possible damages to objects and persons caused by
construction faults, under condition that the entire system be marked CE and only Benincá parts be used.
For an efficient operation of these automatisms, the gate must have the following features:
- good stoutness and stiffness
- all hinges must have positive clearances and permit smooth and regular manual operations.
- when wings are closed their height have to fit together.
Stabilise the height of the automatic system above ground level (it should be as central as possible with respect to the
gate and corresponding to a sturdy cross piece).
Then weld the plate P respecting the distances in fig. 2.
When the gate is closing, weld the bracket S respecting the distance in fig. 3, onto a cross piece of the gate or another
suitably robust element; bear in mind that in this condition the actuator must not be completely at the end of travel.
Remove the protective cover C unscrewing the screw F, then fix the actuator to the plate P with the screw T, the washer
L and the nut D (fig. 3).
Lastly block the actuator on the plate S with the screw V and the washer R.
The holes in the actuator (fig.3A) help you respect the optimum installation distances.
The adjustable fixing brackets, available on request, allow a wider possibility of adapting the actuator to the different
installation conditions, also avoiding cutting and welding the brackets supplied.
The actuator is equipped with electro-magnetic sensors which are adjustable in the opening and closing phases, fit-
ted to mechanical locks as shown in Fig. 3. To adjust, position the "Open" and "Close" mechanical locks, as indicated
hereunder:
1 Release the automatic system by using the special release lever, as shown in the user's instruction manual.
2 Close the gate leaf.
3 Loosen the V1 screw and move the "Close" block until it touches the "P" pin. Then tighten the V1 screw.
4 Open the gate leaf.
5 Loosen the V2 screw and move the "Open" block until it touches the "P" pin. Then tighten the V2 screw
6 Reset the automatic operation.
The actuator is supplied complete with pre-cabled connection cable as follows:
N
Color
1
Black
2
Red
3
White
4
Green
5
Brown
For cable length lower than 5m, use a cable 2x2.5sqmm
For cable length from 5 to 10 m use a cable 2x4sqmm
Cables longer than 10m are not recommended to connect control unit and motor.
10
Warning
General information
Fitting the automatic system
To adjust the limit switches
Connections
Section
Function
1.5mm
Motor -
2
1.5mm
Motor +
2
0.5mm
Common FC - COM
2
0.5mm
Open limit switch -SWO
2
0.5mm
Close limit switch-SWC
2