FAQ. Question
FAQ. Question
What happens if I invert
If you invert the limit switches, the control
the "open" limit switch
unit cannot properly detect the end
with the "close" limit
of the movement by intercepting the
switch?
corresponding limit switch. In this case, the
control unit searches for the mechanical
lock or the maximum stroke saved via
encoder count. This does not generate
malfunctions, but the system loses the
safeties linked to the presence of the limit
switches.
I installed a dual swing
In the ONE system, use of the limit switches
gate and I cannot find
is not necessary. All operators are equipped
the limit switches to be
with electronic limit switches with encoder.
connected. How do I
In the case of sliding applications (single
stop the automation?
operator), there is still the option of using
contact limit switches (electric or magnetic)
only on operator 1 (to provide additional
safety to the application).
Can I use the ONE
YES. To manage the double barrier
system to manage a
LIMIT-ONE, you have to use two ONE
synchronised double
control units, one for each barrier, setting
barrier?
one as MASTER and the other as SLAVE
(using the dip switch #10 of the control
O
1
2
3
4
5
6
7
8
unit). In this way, the MASTER control
N
unit communicates with the SLAVE,
synchronising their movements.
DIP-SWITCH 1 OFF = Automatic Operation
Can I use the ONE
YES. To manage a double slider FORT-
system to manage a
ONE, you have to use two ONE control
1
2
3
4
5
6
7
8
O
N
double sliding gate?
units, one for each slider, setting one
as MASTER and the other as SLAVE
(using the dip switch #10 of the control
DIP-SWITCH 1 ON = Step-by-Step Operation
unit). In this way, the MASTER control
unit communicates with the SLAVE,
O
1
2
3
4
5
6
7
8
synchronising their movements.
N
In the MASTER-SLAVE
In synchronised applications (MASTER-
applications, where do I
SLAVE), the accessories must be
DIP-SWITCH 4 ON = Automatic Closing enabled (pause time 30 sec)
connect the accessories
connected only on the MASTER BUS line.
to the BUS?
1
2
3
4
5
6
7
8
O
N
Which are the dip-switches possible settings?
DIP-SWITCH 3 ON = Deceleration after 60% of the maximum stroke
DIP-SWITCH 3 Off = Deceleration after 80% of the maximum stroke
O
1
2
3
4
5
6
7
8
N
DIP-SWITCH 7 ON = Auxiliary Flashing Light
DIP-SWITCH 7 OFF = Electric lock command
O
1
2
3
4
5
6
7
8
N
DIP-SWITCH 5 ON = Operation with 1 Operator
DIP-SWITCH 5 OFF = Operation with 2 Operators
O
1
2
3
4
5
6
7
8
N
DIP-SWITCH 2 ON = Condominium Operation Enabled
DIP-SWITCH 2 OFF = Condominium Operation Disabled
1
2
3
4
5
6
7
8
O
N
DIP-SWITCH 6 ON = Leaf Delay Enabled (fixed 4" during opening and
closing movement)
DIP-SWITCH 6 OFF = Leaf Delay Disabled (fixed 4" only during closing
movement)
36
COMUNELLO ®Copyright 2015 - All right reserved
9
10
9
10
9
10
9
10
9
10
9
10
9
10
9
10
O
1
2
3
4
5
6
7
8
N
DIP-SWITCH 8 ON = Release Stroke Enabled
DIP-SWITCH 8 OFF = Release Stroke Disabled
1
2
3
4
5
6
7
8
O
N
DIP-SWITCH 9 ON = Slave Control Unit
DIP-SWITCH 9 OFF = Master Control Unit
9
10
9
10