Descargar Imprimir esta página

Installation; Unpacking The Drill; Hoses And Connections; Methods To Prevent Freezing - Chicago Pneumatic CP 0009 Instrucciones De Seguridad Y De Funcionamiento

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
Safety and operating instructions
Data plate
A
C
B
A.
Machine type
B.
Maximum permitted compressed air pressure
Serial number
C.
The warning symbol together with the book
D.
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.
E.
The CE symbol means that the machine is
EC-approved. See the EC declaration which is
delivered with the machine for more
information. If the CE symbol is missing, it
means that the machine is not EC-approved.
Noise level label
WA
xxx
dB
The label indicates the guaranteed noise level
corresponding to EC-directive 2000/14/EC. See
"Technical data" for accurate noise level.
Safety label
To avoid injury, before using or servicing tool, read
and understand separately provided safety
instructions.
12

Installation

Unpacking the drill

Plastic guards
Before the drill is used for the first time remove all
the plastic guards from the hose nipples.
D
E
Lubricate
After unpacking and installing the tool, pour a liberal
amount of lubrication oil in the air connection.

Hoses and connections

A.
B.
C.
D.

Methods to prevent freezing

Ice formation in the muffler can occur when the
ambient air temperature is 32-50 °F (0–10°C) and
the relative humidity is high.
The machine is designed to avoid the formation of
ice in the muffler. Despite this, under extreme
conditions ice can form in the muffler.
A
B
Compressed air source
Water separator (optional)
Oiler (optional)
Max. 10 feet (3 meter) compressed air hose
between the oiler and the machine.
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar
(e)).
The maximum permissible air pressure, 90 psig
(6.2 bar (e)), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the machine.
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 meters), a hose with a minimum internal
diameter of
3
in. (19 mm) should be used. If the
4
hose length is between 100 and 330 feet (30 and
100 meters), a hose with a minimum internal
diameter of 1 in. (25 mm) should be used.
9800 0547 90c | Original instructions
CP 0009, CP 0014
D
C

Publicidad

loading

Este manual también es adecuado para:

Cp 0014