Descargar Imprimir esta página

Operation, Precautions - Chicago Pneumatic CP 0009 Instrucciones De Seguridad Y De Funcionamiento

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 66
CP 0009, CP 0014
WARNING
Ejected insertion tool
If the tool retainer on the machine is not in a locked
position, the inserted tool can be ejected with force,
which can cause personal injury.
Never start the machine while changing the
insertion tool.
Before changing the insertion tool or accessories,
stop the machine, switch off the power supply
and bleed the machine by activating the start and
stop device.
Never point the inserted tool at yourself or anyone
else.
Make sure that the insertion tool is fully inserted
and the tool retainer is in a locked position before
the machine is started.
Check the locking function by pulling the inserted
tool outwards forcefully.
WARNING
Moving or slipping insertion
tool
An incorrect dimension of the inserted tool s shank
can result in that the inserted tool is lost or is slipping
out during operation. Risk of severe injury or crushed
hands and fingers.
Check that the insertion tool has the shank length
and dimensions that the machine is intended for.
Never use an insertion tool without a collar.

Operation, precautions

DANGER
Explosion hazard
If a warm insertion tool comes into contact with
explosives, an explosion could occur. During
operation with certain materials as well as use of
certain materials in machine parts, sparks and
ignition can occur. Explosions will lead to severe
injuries or death.
Never operate the machine in any explosive
environment.
Never use the machine near flammable materials,
fumes or dust.
Make sure that there are no undetected sources
of gas or explosives.
Never drill in an old hole.
9800 0547 90c | Original instructions
Safety and operating instructions
WARNING
Unexpected movements
The inserted tool is exposed to heavy strains when
the machine is used. The inserted tool may break
due to fatigue after a certain amount of use. If the
inserted tool breaks or gets stuck, there may be
sudden and unexpected movement that can cause
injuries. Furthermore, losing your balance or slipping
may cause injury.
Make sure that you always keep a stable position
with your feet as far apart as your shoulder width,
and keeping a balanced body weight.
Always inspect the equipment prior to use. Never
use the equipment if you suspect that it is
damaged.
Make sure that the handles are clean and free of
grease and oil.
Keep your feet away from the inserted tool.
Stand firmly and always hold on to the machine
with both hands.
Never drill in an old hole.
Never start the machine when it is lying on the
ground.
Never 'ride on the machine with one leg over the
handle.
Never strike or abuse the equipment.
Check regularly for wear on the insertion tool,
and check whether there are any signs of damage
or visible cracks.
Pay attention and look at what you are doing.
WARNING
Stalling hazard
If the insertion tool gets caught during operation,
the whole machine will start to rotate if you lose
your grip on it. This unexpected rotation of the entire
machine may cause serious injury or death.
Stand firmly and always hold onto the machine
with both hands.
Make sure that the handle or handles are clean
and free from grease and oil.
Never drill in an old hole.
WARNING
Trapping hazard
There is risk of neck ware, hair, gloves and clothes
getting dragged into or caught by a rotating
insertion tool or accessories. This may cause choking,
scalping, lacerations or death. To reduce the risk:
Never grab or touch a rotating drill steel.
Avoid wearing clothing, neck ware or gloves that
may get caught.
Cover long hair with a hair net.
7