1 Introduction
This quick guide will assist you in starting up the unit. Follow
the safety notices or injury to health or property damage may
occur. Carefully read the original operating instructions in-
cluding information on maintenance and troubleshooting
prior to startup. These are located on the included CD and on-
line at
www.buehler-technologies.com
Please direct any questions to:
Bühler Technologies GmbH
Harkortstraße 29
40880 Ratingen
Germany
Tel.: +49 (0) 21 02 / 49 89-0
Fax: +49 (0) 21 02 / 49 89-20
These operating instructions are a part of the equipment. The
manufacturer reserves the right to change performance-, spe-
cification- or technical data without prior notice. Please keep
these instructions for future reference.

1.1 Scope of delivery

P2.2 / P2.82 AMEX
1 x Sample gas pump with
motor
4 x Rubber-metal bumpers
1 x Mounting bracket
Product documentation

1.2 Intended use

Sample gas pumps are intended
• for installation into sample gas conditioning systems in
industrial applications and
• to transport only gaseous media
This unit may only be used if:
• The product is being used under the conditions described
in the instructions, used according to the nameplate and
for applications for which it is intended. Any unauthor-
ized modifications of the device will void the warranty
provided by Bühler Technologies GmbH,
• Compliance with the threshold values specified in the
data sheet and the instructions,
• Monitoring equipment / protection devices are connected
correctly.
Please refer to the original operating instructions on the in-
cluded CD for details.
The AMEX versions are suitable for use in Class I, Div. 2,
Groups B, C, D.
8
Bühler Technologies GmbH
P2.4 / P2.84 AMEX
1 x Pump body with intermedi-
ate flange
1 x Motor
1 x Coupling flange
1 x Coupling
1 x Mounting ring
Product Documentation
NOTICE
Restriction for AMEX pumps
The P2.8x AMEX pumps can pump exclusively non-flammable
gaseous media and flammable gaseous media that are clearly
above the upper explosive limit or clearly below the lower ex-
plosive limit.
The P2.2-, P2.4- AMEX pumps can pump non-flammable
gaseous media and flammable gaseous media that could oc-
casionally be explosive in normal operation (Sampling zone 1).
Sampling gas from zone 1 is generally forbidden if the gas
flow leads to a dangerous electro-static charge in the bellow /
pump body (also see the "Operation" section).
The AMEX versions are intended for use in Class I, Div. 2,
Groups B, C, D.
When installed outdoors, ensure adequate protection from
the weather, see chapter Requirements to the installation site
2 Safety regulations
This product has no dangerous ignition sources when ob-
serving regulations and operating parameters in these oper-
ating instructions. Installation into a complete system can
pose new hazards the manufacturer of this sample gas pump
has no control over. If necessary, perform a risk assessment of
the complete system this product will be installed into.
Observe the relevant national safety regulations for the in-
stallation site and the generally applicable state of the art
when configuring and building the complete system. These
can be determined through applicable harmonised standards,
e.g. EN 60079-14 among others. Additional national regula-
tions pertaining to initial operation, operation, maintenance,
repairs, and disposal must be observed.
Avoid any exothermic reactions in your system, do not use
materials with a catalytic effect in the conveyor lines. Danger-
ous rises in temperature may otherwise occur. Sample gas
pump materials in contact with mediums are specified in this
operating manual to facilitate the safety assessment.
Adiabatic compression is part of the physical operating prin-
ciple of bellows pumps. Dangerous rises in temperature can-
not be ruled out when exceeding the operating parameters.
Avoid these dangerous conditions. If necessary, protect the en-
tire system against flashback. Follow these notes and the ap-
plicable national regulations and prevent malfunctions to
avoid personal injury and property damage.
The operator of the system must ensure:
• The equipment is installed by a professional familiar with
the safety requirements and risks,
• Safety notes and operating instructions are available and
observed,
• The permissible data and operating conditions are ob-
served,
• Protective devices are used and the required maintenance
is performed,
• The unit is disposed according to the law.