when fully coded.
All other detectors, except the one you want to program, must be off for the
Ÿ
programing to take place.
The PIR detector can only be installed indoor. The rate of false alarm is greatly
Ÿ
influenced by the installation position. The best installation height is about 2-2.2
meters from ground.
Avoid installing facing the windows, air conditions, fire stove, and sun light because
Ÿ
the temperature difference is big and air velocity is fast in these places.
When using the PIR detector which is not pet-friendly, please put the pets in the place
Ÿ
in which can not be detected by the PIR detector in the status of arm.
If the light of the PIR detector flashes means the battery is not enough and needs to be
Ÿ
changed immediately.
Delete detectors
In the status of disarm, press [SET] button lightly, the host will make a short
beep, the 7 blue LED light will be on and then voice prompts "enter setup, remote
controller coding". Press [SET] button lightly again, then the first blue LED light will be on
and the voice prompts "detector coding". Then long press [SET] button right now, all the
detectors in the defense zone 1 will be deleted. Press [SET] button lightly again, then the
second blue LED light will be on, the voice prompts "detector coding". Then long press
[SET] button right now, all the detectors in the defense zone 2 will be deleted; The
method of deleting detectors of other defense zones is same.
Caution: If 10 detectors are coded into one zone, delete any detector from this zone, all
detectors in this zone will be deleted.
Zone names
You can set a name for each of the 10 zones to identify easily the alarm location.
To set zone names select „Zone names" app option or send a SMS with:
programming password + [90] + zone number (01-07) + zone name (30 characters) + # .
For example: to set the name „main entrance" to zone 3 send SMS: 88889003main
entrance# .
Note:
The app is made for 99 zones alarm systems, for this model you can only name the
Ÿ
first 7 zones for the 7 wireless zones and the last 3 for the 3 wired ones.
Record zone names
To record zone names select „Record zone names" or send SMS:
programming password + [92] + zone number (01-07) + [1] + # to record the zone's
Ÿ
name then speak to the control unit. The recording lasts10 sec. After that the unit will
replay the recording.
programming password + [92] + zone number (01-07) + [2] + # to delete recording
Ÿ
programming password + [92] + zone number (01-07) + [3] + # to listen the recording
Ÿ
Set alarm address
If you have multiple alarm systems you can set the address for each of them to