13.56 MHz
Upgradable readers ARC
Installation instructions
-
-
-
-
-
-
- Check that the cable length that comes out of the module does not exceed 0.39 in. If
it does, push the excess cable into the module housing.
- Connect the cable of the module to connector J9. You should not have a loop
- Insert the module into the reader slot (until you hear a "click" for SE6)
- Cut the base as shown in the drawing
- Place the reader + module on the base (i.e. Mounting), use the 2 screws provided
(3)
with the module
.
(2)
To pass the module cable into
the
support,
cut
preformed part of the support.
Option:
Reinforcement plate to rigidify the
assembly:
- Standard/keyboard reader +
biometric module: Ref. SE7-
ARC-DE.
- Touch screen reader +
biometric module: Ref. SE7-
ARC-F.
STid guarantees the good working order, compliance, technical
support and after-sales service of the readers and modules (SE6
and SE8) that are installed as explained above, without any internal
or external modifications.
STid declares that the ARC-X reader is compliant with the essential requirements of the Directives RED 2014/53/EU and RoHs 2011/65/EU. A copy of our
declaration is available on request from qualite@stid.com.
This device complies with Part 15 of the FCC rules and with ISED's license–exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such
modifications could void the user's authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use.
In accordance with the provisions of the Environment Code, STid finances the collection, decontamination and recycling of WEEE provided by
ESR-RECYLUM, to which STid adheres and to which it has transferred its regulatory responsibilities as a Producer.
STid recommends that owners of used equipment who wish to dispose of it return it as WEEE by contacting ESR / RECYLUM in order to benefit
from the solutions at no additional cost of collecting and recycling used equipment. More information on www.recylum.fr.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C13 - Page 4 sur 12 - Ed. 08/04/2019
13,56 MHz
Lecteurs évolutifs ARC
Notice d'installation
Pass the cables through the hole in the base.
Screw the base in its final location.
Connect the reader.
Test the readings and communication.
Place the reader on the base (clip the top part and then pivot it down).
Lock the reader with the two screws provided using the specific tool.
Procedure to add the biometric (SE6) or 125 kHz module (SE8)
(2)
.
out
the
Screw
Mounting
(1)
.
(3)
Declaration of compliance
"DEEE Pro" Member
13.56 MHz
Lectores escalables ARC
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
(3)
(3)
Slot for the passage
of the 125 kHz
module cable
SE8
(3)
US
FR
ES
Slot for the
passage of
the biometric
cable
SE6
(1)