Features:
Our ET8 signal chart recorder offers the flexibility of a standardized input recorder and can be used for a
wide variety of applications. Featuring high/low audible alarm, large display, and two input channels. The
ET8 offers features normally offered only on higher priced chart recorders.
Remote sensing capability with powered voltage or current transmitters
High/Low Alarms feature and display of Min/Max readings (no controller/relay functions)
User selectable output ranges and recording times
Two screw terminals on back of instrument for easy connection of input transmitter
User calibration

Product Specifications

Input Ranges:
Output Range:
Accuracy:
Sensor Capability:

Display Resolution:

Chart Size:
Recording Time:
Average Response Time:
Ambient Operating Range
(recorder):
Calibration Adjustment:
Alarms:
Power Supply:
Maximum Input Voltage:
Mounting:
Dimensions:
Weight:
Applications:
Rev. 10/07
0-20mA, 4-20mA, 0-5Vdc, 1-5Vdc (user-selectable)
000.0 to +100.0, 0000 to +1000, 00.00 to +14.00, 000.0 to +150.0,
000.0 to +200.0, 000.0 to +300.0, -10.00 to +10.00, -150.0 to
+250.0
0.3% full scale, ±1 digit (recorder only)
Any powered voltage or current transmitter with specified recorder
input range (see input ranges above)
0.001, 0.01, 0.1 or 1 depending on range selected
8" DIA (20.3 cm)
24 hour, 7 day (user-selectable)
20 seconds full scale, depending on transmitter
0 to 90% RH (non-condensing) +32 to +122°F (0 to +50°C)
User zero calibration
HIGH/LOW, Audio/Visual
120V AC adapter, (other adapters can be obtained for international
markets), 9V battery used for back-up power
(not-included)
5 volts (instrument records direct current - DC)
Freestanding or wall mounting (keyholes)
9.2" x 9.2" x 3.1" (23.4cm x 23.4cm x 7.9cm)
Approximately 4 lbs. (1.8kg) with batteries