Translation of the original operating instructions
To do this, insert the ignition key provided in the igni-
tion key switch (fig. 13) and along the direction "Start".
Let go of the ignition key after max. 10 seconds and the
engine should now run.
If the engine does not start after 10 seconds, you
should wait for at least 1 minute before the next at-
tempt. This process may only be repeated a maximum
of 3 times and then the electric starter must be allowed
to cool down for at least 15 minutes. Disregarding this
can cause the damage to the starter and/or engine. Do
not attempt to start the engine when it is already running!
5. After a brief warm-up phase, slide the choke back again. Now
you can set the changeover switch (fig. 2, no. 21) to the operat-
ing voltage your require 230 V~ or 400 V~ (230 V~ = top; 400
V~ = bottom).
6. Insert the plug of the consumer into the corresponding socket of
the electric generator. Switch the circuit breaker on. Then switch
on the consumers on after the other.
Observe the running of the engine as well as the colour of the exhaust gas once started.
The engine running should settle down after a few minutes. The voltmeter should show
230 V or 400 V.
The 12 V outlet of the generator is not a voltage-controlled connection and
hence is not suitable for charging batteries.
The installed battery must not be connected to the 12 V connection of
the electric generator because it is separately charged via an alternator.
6.3.
Starting the motor with the pull starter
1. Disconnect all consumers from the power supply (fig.
14, 17, 18 & 19) and switch the ignition to "ON".
2. Set the fuel cock at the fuel filter to "open" ("1").
Please see figure 12.
3. Set the choke lever to "Pulled" ("1").
4. Set the ignition lock (Fig. 13) to start.
5.
Carefully pull the pull-cord starter (fig. 15, no. 9) until
you can feel a light resistance, then pull it
Attention! Injury!
A setback can occur unexpectedly on the pull
starter, which suddenly blocks the rope.
quickly and forcefully.
After a brief warm-up phase, return the choke lever.
Corresponding devices can now be connected and started.
Note that only the 230 V~ outlets or the 400 V~
outlet can be operated at any given time.
Observe the motor operation and the color of the exhaust gas
after the drain. The motor operation should stabilize after a few
seconds. The voltmeter should display 230 V.
13
14
15
16
10
29