Error search
Error
Possible cause
Filter does not stop automatically after
Steady contact between sensor and filter case
set time
No water comes out of the spray
 Fine filter or spray nozzles are blocked
nozzles while the clean pump is
 It is air in the cleaning pump
working
Filter does not start
Contact switch has no contact
Unfiltered water comes out of the outlet
 Entering water runs over the rubber seal
 Damaged Filter element
Blocked wastewater outlet
Wrong angle of wastewater outlet
Filter elements are not getting cleaned
 Clean pressure is too low
enough
 Cleaning time is too short
Filter does not start automatically to
 Water level in drum is too low
clean in mode „Auto"
 Wrong installation of sensor
Accessories:
Art. No.
Description
2880-1
FIAP TrommelSieve Active element 30, 40, 60, 100 Mikron
2880-2
FIAP TrommelSieve Active cleaning pump
2880-3
FIAP TrommelSieve Active spray nozzle
2880-4
FIAP TrommelSieve Active ball valve DN 100
2427
FIAP GateValve Active 110 mm
2428
FIAP GateValve Active 160 mm
Installation drawing of FIAP TrommelSieve Active gravity version.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Solution
Remove any objects which can cause
contact between the sensor and the
filter case
 Clean fine filter and spray nozzles
 Remove any air out of the cleaning
pump
Ensure the contact. Close the cover
with more pressure
Check the correct fitting of rubber
seal
 Check installation of filter
 Replace damaged filter elements
Correct the angle of wastewater outlet
 Set a higher clean pressure
 Set a longer cleaning time
 Check the filter elements for
damages
 Check the installation of sensor
34
www.fiap.com

Publicidad

Tabla de contenido
loading