7. Select Battery Type
Press UP/DOWN key to select battery type, i.e. Regular Flooded, AGM Flat Plate or AGM
Spiral, and GEL Battery.Press UP/DOWN key to select battery type, and press OK key to
confirm.
8. Battery System Standard and Rating
Use UP/DOWN key to select according to the actual system standard and rating
marked on the battery. See in the below picture, the arrow indicated location.
CCA
Cold Cranking Amps, specified by SAE&BCI, most frequently used value
for starting battery at 0°F (-18°C)
BCI
Battery Council International standard
CA
Cranking Amps standard, effective starting current value at 0°C
Marine Cranking Amps standard, effective starting current value at 0°CJapan
MCA
Industrial Standard, displayed on the battery as combination of the numbers and
letters, e.g. 55D23,80D26.
DIN
German Auto Industry Committee Standard
Internal Electro technical Commission Standard
IEC
EN
European Automobile Industry Association Standard
SAE
Society of Automotive Engineers Standard
GB
China National Standard.
Input correct test standard and rating, press OK key, tester starts to test, and dynamic
interface "TESTING" prompted. See above.