Communication Modules
4. Position the Communication Module so that the connector on the bottom of
the Module aligns with the connector on the base unit.
Tighten this
screw first.
Captive Screws
5. Push down on Communication Module until connector is firmly seated.
6. Tighten the three captive screws that secure the module to the terminal,
starting with the bottom, left screw on the module. Tighten screws to a
torque of .34 - .45 N•m (3 - 4 in-lb).
To replace a Communication module:
1. Disconnect power from the terminal.
2. Disconnect communication cables from the Communication Module.
3. Loosen the 3 screws that secure the Communication Module to the terminal.
4. Carefully lift the Communication Module away from terminal and set aside.
5. Follow installation steps 4 - 6 above.
Publication 2711P-IN017A-MU-P