Roland JP-8080 Manual Del Usuario página 200

Tabla de contenido

Publicidad

Poly
(Controller number 127)
status
2nd byte
3rd byte
BnH
7FH
00H
* This is received only when Remote KBD CH ([MIDI]) is ALL or when the MIDI
channel of the poly message matches.
* The same processing will be performed as when All Note Off is received, and [MONO]
will be turned off for the patch of the part specified by PANEL SELECT.
System Realtime messages
Active Sensing
status
FEH
* When an Active Sensing message is received, the unit will begin monitoring the
intervals of all further messages. During monitoring, if more than 400 ms passes
without a message being received, the same processing will be done as when All Note
Off and Reset All Controllers messages are received. Then monitoring will be halted.
Timing Clock
status
F8H
* This is received when MIDI Sync ([MIDI]) is set to REMOTE KBD IN.
Start
status
FAH
* This is received when MIDI Sync ([MIDI]) is set to REMOTE KBD IN.
Continue
status
FBH
* This is received when MIDI Sync ([MIDI]) is set to REMOTE KBD IN.
Stop
status
FCH
* This is received when MIDI Sync ([MIDI]) is set to REMOTE KBD IN.
System Exclusive messages
* This is always received, regardless of the Rx Exclusive SW ([MIDI]) setting.
status
data byte
status
F0H
iiH, ddH, ......, eeH
F7H
F0H:
System Exclusive message status
ii = ID number:
This is the ID number (manufacturer ID) that specifies the manufacturer
whose exclusive message this is. RolandÕs manufacturer ID is 41H. ID
numbers 7EH and 7FH are defined in an expansion of the MIDI
standard as Universal Non-realtime messages (7EH) and Universal
Realtime Messages (7FH).
dd,..., ee = data:
00H - 7FH (0 - 127)
F7H:
EOX (End Of Exclusive)
Data Set 1
DT1
This message transmits the actual data, and is used when you wish to set the data of the
receiving device.
status
data byte
F0H
41H, dev, 00H, 06H, 12H, aaH, bbH,
ccH, ddH, eeH, ... ffH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
(Roland)
dev
device ID
(dev: 10H - 1FH, factory setting is 10H)
00H
model ID
(JP-8080)
06H
model ID
(JP-8080)
12H
command ID
(DT1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
eeH
data: The actual data to be transmitted. Multi-byte data is transmitted in the
order of the address.
:
:
ffH
data
sum
checksum
F7H
EOX
(End Of Exclusive)
* Only data set 1 for patch parameters and performance parameters is received. For
patch parameters, this message will affect the patch parameters of the part selected by
PANEL SELECT at that time, regardless of the parameter address which was received.
* For details on address, size, and checksum settings, refer to ÒExamples of exclusive
messages and calculating the checksumÓ (p.206).
* Data whose size is greater than 256 bytes should be divided into packets of 256 bytes
or less and transmitted. Successive ÒData Set 1 messages should have at least 20 ms of
time interval between them.
status
F7H
199

Publicidad

Tabla de contenido
loading