EN
The product shall be stored in package in compliance with the conditions of impact of
climatic factors the temperature not lower than minus 35°C.
Warranty storage period shall amount to maximum 6 months.
3.7 TRANSPORTATION
The table in package can be transported by all transportation means, except for the air
transport.
The following shall be provided for transportation:
- protection against mechanical damages;
- placement and fixing of the packed container in transportation means shall provide
for stable position and shall exclude any possibility of movement during transportation.
MOVE THE TABLE ONLY IN HORIZONTAL POSITION!
3.8 RECOMMENDATIONS FOR WASTES REMOVAL AND DISPOSAL AND
ENVIRONMENT PROTECTION
Local requirements to environment protection shall be taken into account and
observed. Substances hazardous for water shall not ingress into the water reservoirs, soil, and
sewage system.
The issue of wastes collection and disposal shall be timely resolved without any harm
to environment (ground water, soil). Disposal shall comply with the local regulations currently
in force.
When preparing and sending the table for disposal it shall be disassembled; table
components shall be sorted by construction materials.
Table 3
LIST OF POSSIBLE FAILURES
and troubleshooting
Type of failure, Manifestation,
Additional signs
1
1. Refrigerated table does not
work; key switch indicator
lamp does not light
2. Refrigerated table is working
continuously for a long time.
The temperature is not kept
at the set level in the internal
volume.
24
HANDLE WITH CARE! DO NOT TURN OVER!
No electric power on the key
switch terminals
Frequent table loading with
ward food-stuff.
Frequent door opening.
Evaporator is covered with thick
ice layer.
Tightness
system is damaged.
Potential reason
2
of
refrigerating
Remedies
3
Check condition of power
cable and repair it, if
required.
Check
voltage
Avoid table loading with
warm and hot food-stuff.
Reduce
the
food-stuff
turnover.
Defrost evaporator; reduce
intervals
between
defrosting, and increase
duration of defrosting.
Detect leakage and recover
supply