Transportation And Storage; Inspect The Delivery; Transportation Guidelines; Storage Guidelines - Lowara e-SV Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
en - Translation of the original instructions
FULFILS THE RELEVANT PROVISIONS OF THE FOLLOWING EU-
ROPEAN DIRECTIVES:
• MACHINERY 2006/42/EC (THE TECHNICAL FILE IS AVAILA-
BLE FROM LOWARA SRL UNIPERSONALE).
AND OF THE FOLLOWING TECHNICAL STANDARDS:
• EN 809
MONTECCHIO MAGGIORE, 16.06.2011
AMEDEO VALENTE
(DIRECTOR OF ENGINEERING AND R&D)
rev.01
Lowara is a trademark of Lowara srl Unipersonale, subsidiary of Xylem Inc.

2 Transportation and Storage

2.1 Inspect the delivery

1.
Check the outside of the package for evident signs of damage.
2.
Notify our distributor within eight days of the delivery date, if the
product bears visible signs of damage.
Unpack the unit
1.
Follow applicable step:
If the unit is packed in a carton, remove the staples and open the
carton.
If the unit is packed in a wooden crate, open the cover while pay-
ing attention to the nails and straps.
2.
Remove the securing screws or the straps from the wooden base.
Inspect the unit
1.
Remove packing materials from the product.
Dispose of all packing materials in accordance with local regulations.
2.
Inspect the product to determine if any parts have been damaged or
are missing.
3.
If applicable, unfasten the product by removing any screws, bolts, or
straps.
For your personal safety, be careful when you handle nails and straps.
4.
Contact your Sales and Service Department if anything is out of order.

2.2 Transportation guidelines

Precautions
WARNING:
• Observe accident prevention regulations in force.
• Crush hazard. The unit and the components can be heavy.
Use proper lifting methods and wear steel-toed shoes at all
times.
Check the gross weight that is indicated on the package in order to select
proper lifting equipment.
Position and fastening
The unit can be transported either horizontally or vertically. Make sure that
the unit is securely fastened during transportation, and cannot roll or fall
over.
WARNING:
Do not use eyebolts screwed on the motor for handling the
whole electric pump unit.
• Use straps surrounding the motor if the power of the motor is between
0.25 kW and 4.0 kW.
• Use ropes or straps that are linked to the two flanges (eye bolts if provi-
ded) located near the mating zone between the motor and pump, if the
power of the motor is between 5.5 kW and 55.0 kW.
• Eyebolts screwed onto the motor may be exclusively used to handle the
individual motor or, in case of a not balanced distribution of weights, to
partially lift the unit vertically starting from a horizontal displacement.
• To move the pump unit only, use straps firmly linked to the motor adapt-
er.
For more information about how to securely harness the unit, see Figure 4.
Unit without motor
If the unit is not delivered with a motor, the calibrated fork-shaped shim is
already inserted between the adapter and the transmission coupling. The
10
shim is inserted to keep the impeller stack in the correct axial position. In
order to prevent damage during transportation the shaft is also held into
place with expanded polystyrene and plastic straps.
The bolt and nuts used to fasten the motor are not included. For more in-
formation about how to couple the motor, see Figure 23.
WARNING:
A pump and motor that are purchased separately and then cou-
pled together results in a new machine under the Machinery di-
rective 2006/42/EC. The person making the coupling is respon-
sible for all safety aspects of the combined unit.

2.3 Storage guidelines

Storage location
The product must be stored in a covered and dry location free from heat,
dirt, and vibrations.
NOTICE:
• Protect the product against humidity, heat sources, and mechanical dam-
age.
• Do not place heavy weights on the packed product.
Ambient temperature
The product must be stored at an ambient temperature from -5°C to +40°C
(23°F to 104°F).

3 Product Description

3.1 Pump design

This is a vertical, multistage, non-self priming pump, which can be coupled
to standard electric motors. The pump can be used to pump:
• Cold water
• Warm water
The metallic parts of the pump that come in contact with water are made of
the following:
Series
Material
1, 3, 5, 10, 15, 22 Stainless steel
33, 46, 66, 92, 125 Stainless steel and cast iron
A special version is available where all parts are made of
stainless steel.
The SV pumps 1, 3, 5, 10, 15, and 22 are available in different versions ac-
cording to the position of the suction and delivery ports and the shape of
the connection flange.
The product can be supplied as a pump unit (pump and electric motor) or
only as a pump.
NOTICE:
If you have purchased a pump without motor, make sure that the motor is
suitable for coupling to the pump.
Mechanical seal
Series
Basic characteristics
1, 3, 5
Nominal diameter 12 mm (0.47 in.), unbalanced, right hand
rotation, K version (EN 12756)
10, 15, 22
Nominal diameter 16 mm (0.63 in.), unbalanced, right hand
rotation, K version (EN 12756)
Balanced with motor power ≥ 5 kW
33, 46, 66,
Nominal diameter 22 mm (0.86 in.), balanced, right hand ro-
92, 125
tation, K version (EN 12756)
Intended use
The pump is suitable for:
• Civil and industrial water distribution systems
• Irrigation (for example, agriculture and sporting facilities)
• Water treatment
• Boiler feed
• Washing plants
• Cooling (for example, air conditioning and refrigeration)
• Fire fighting applications
e-SV - English

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido