Operating Instructions
GB
Dear Customer,
Congratulation on purchasing
your new STEINEL sensor and
thank you for the confidence
you have shown in us. You have
chosen a high-quality product
that has been manufactured,
tested and packed with the
greatest care.

Safety Precautions

í Disconnect the power supply
before attempting any work
on the sensor!
í During installation, the elec-
tric power cable to be con-
nected must be dead. There-
fore, switch 'OFF' the power
first and use a voltage tester
to make sure the wiring is off
circuit.

Assembly/Installation

The sensor is only suitable for
recessed ceiling installation in-
doors. A clamping-type ceiling
adapter or surface-mounting
adapter is not included.

System Components

Load module
Sensor module
Sensor base
Dip switches
(1) Normal mode/Test mode
(2) Semi- / fully automatic
mode
(3) Button/switch
(4) 'ON' / 'ON-OFF' button
(5) Constant-lighting control
'ON'/'OFF'
Please familiarise yourself with
these instructions before at-
tempting to install the product
because prolonged, reliable and
trouble-free operation will only
be ensured if it is fitted and used
properly.
í Installing the sensor involves
work on the mains power
supply. This work must there-
fore be carried out profes-
sionally in accordance with
the applicable national
wiring regulations and elec-
trical operating conditions
(VDE 0100).
(see fig. on page 2)
Sensor and load module come
ready assembled and must be
plugged together after fitting
the load module and setting
the potentiometers/dip switch-
es. The sensor module must
now be locked in place with the
catch mechanism
, using a
screwdriver if necessary.
Twilight setting
Time setting
Switching output 1
Basic brightness
Reach setting (IR)
Reach setting (HF)
k
Kaiser stud-wall junction box,
1 0.
1
optional
k
Clamping-type ceiling
1 0.
2
adapter, optional,
- 18 -
We hope your new STEINEL
sensor will bring you lasting
pleasure.
Accessories:
Kaiser junction box for stud
walls
EAN No.: 4007841 000370
Clamping-type ceiling adapter
EAN No. 4007841 002855
Surface-mounting adapter,
EAN No.: 4007841 000363
Guard cage,
EAN No.: 4007841 003036
Service remote control RC 3,
EAN No.: 4007841 000387
User remote control RC 5,
EAN No.: 4007841 592806
Surface-mounting adapter
IP 54, optional
Locking mechanism
Assembly/Installation
Parallel-connected
configurations
Shrouds for minimising the
detection zone (HF 360 DALI)