TROUBLESHOOTING, CAUSES, SOLUTIONS

Troubleshooting

1
The indicator
flashed.
2
The indicator
is on.
The indicator
stays on even after pres-
3
sing the button
.
4
The indicator
flashed.
5
The indicator
stays on.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
GYSFLASH 15.24 XTREM
Causes
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
Charge failure, battery non recoverable.
Thermal protection
Charger in sleep mode
Charging interrupted by pressing the
.
mode button
Solutions
• Check that the clamps are connected correctly
• Check that the selected voltage matches the
battery voltage.
Change the battery and press the mode button
to restart a charge.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press mode button
or connect a battery to the
charger to wake up from standby
Press the mode button
again to restart the
load.