Area of application

Can be used in conjunction with:
• Pressurised storage heaters
• Thermally controlled instantaneous heaters
• Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.

Technical data

• Flow pressure
min. 0.5 bar / recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar, install a pressure-reducing
valve.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 3 bar flow pressure:
• Temperature
Hot water inlet:
Recommended (energy saving):
• Supply voltage (transformer 230 V AC/12 V AC):
• Power consumption:
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range with Kodak Gray Card, grey page,
8 x 10", landscape (factory setting):
• Type of protection: - Fitting
- Transformer
• Water connection
Special accessory, see Replacement parts, fold-out page I.
• The following settings can be made and changed with the
infrared remote control (Prod. no. 36 206):
• Set reception range (5 - 18cm)
• Set run-on time (0 - 10 s)
• Set and activate continuous running
(thermal disinfection)
• Switch off fitting
• Restore basic settings
• Test mode = waterless simulation
• Set safety shut-off (5 - 420 s)
• Activate and set automatic flushing
• Special spanner (Prod. no.: 19 132) for removal of flexible
hoses.
• Theft-proof aerator (Prod. no.: 36 133).
• Vandalism-inhibiting, concealed mixer spindle
(Prod. no.: 36 209).
• Base for increasing height of fitting and sensor system
(Prod. no.: 36 210).
• Vandalism-inhibiting, rotation lock (Prod. no.: 42 919).
The rotation lock cannot be combined with the base.

Safety notes

• Installation is only possible in frost-free rooms.
• The transformer is only suitable for indoor use.
• In the case of damage to the external transformer
connection cable, this must be replaced by the manufacturer
or his customer service department or an equally qualified
person, in order to prevent a hazard.
• For cleaning purposes, the transformer plug-in connector
must not be directly or indirectly sprayed with water.
• The voltage supply must be separately switchable.
max. 10 bar
16 bar
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
approx. 6 l/min
max. 70 °C
The conformity declarations can be obtained from the following
60 °C
address:
230 V
3.2 VA
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
60 s
D-32457 Porta Westfalica
1 s
approx. 13cm
IP 59 K
IP 44
cold - right
Installation
hot - left
Flush pipes thoroughly.
Installation
Refer to the dimensional drawing on fold-out page I.
Fasten fitting to basin, see fold-out page II, Figs. [1] and [3].
Connection
The cold water supply must be connected on the right and the
hot water supply on the left.
Screw adapter (A) together with seal (A1) or the filter (B) onto
the service valve, see Fig. [4].
In order to ensure permanent, trouble-free operation,
installation of the enclosed adapter with dirt filter and
non-return valve is mandatory.
Open hot and cold water supply and check connections
for leakage.
Connecting voltage supply
Connect control electronics with plug-in connector (C) to
transformer (D), see Fig. [5].
Connect voltage supply via transformer (D).