MAINTENANCE
Note:
Turn off the unit and unplug it before any maintenance or repair begins to avoid electric
shock.
CLEANING
Unplug the unit before any cleaning. Clean the housing with a soft moisture cloth. Do not
use chemical solvent (such as benzene, alcohol, gasoline). The surface may be damaged or
even the whole case may be deformed. Do not sprinkle water on the unit.
STORING THE DEVICE
If the dehumidifier is not used for a longer period of time:
• Unplug the power cord from the socket and roll it.
• Empty the tank entirely of water and make sure that there is no water inside.
• Store the dehumidifier in a cool, dry place, inaccessible to sun rays, high temperature or
excessive dust.
TROUBLE SHOOTING
Before contacting the service centre, you should compare the symptoms given by the
device with those listed below. The list includes normal situations which are not caused by
a manufacturing defect or defective material.
Problem
The tank fill
indicator lights up
in red.
Insufficient air
drycing
The LED display
indicates "E1"
The power supply
button is flashing.
14
14|EN
Possible cause
The tank is full.
The float is filled with water.
There is no float in the tank.
The detector (magnetic element) in the
float is not positioned properly.
The air flow is prevented.
The air inlet and outlet are blocked.
The ambient temperature is very low.
Failure of the temperature and humidity
sensor.
The machine defrosts at low tempera-
ture.
Solution
Empty the tank.
Empty the float.
Position the float properly.
Position the detector properly.
Leave 50 cm around the device.
Restore patency of the inlet and outlet.
Change the ambient temperature.
Contact the manufacturer's customer service.
Normal condition.
Wait until the defrosting is completed.