To ensure maximum lamp life, provide a minimum clearance of 10cm (4 inches) around the fan and air
vents. Make sure the ambient temperature will not exceed 40°C (104°F) and do not place the fixture
on or nearby a loudspeaker.
Mounting bracket
Swivel lock
Thumb screw
Figure 1
OPERATION:
Read "IMPORTANT INFORMATION BEFORE USE" first and verify all precautions are fulfilled before
operating.
Make sure the correct lamp is installed, read "SERVICE" how to replace the lamp.
The KMAX is fully automated. The lamp turns on as soon as power is applied and the effects start
moving as soon as sound is picked up by the built-in microphone. The sound sensitivity control is
on the back panel of the fixture. Turn clockwise to increase or counter-clockwise to decrease the
sensitivity.
Although the fixture cannot be dimmed, it may be switched on and off remotely using switch packs or
the full-on and full-off levels on dimmer packs. Disconnect the fixture from AC power when not in use.
SERVICE:
There are no user serviceable parts inside except the lamp and fuse. Refer all service to a qualified
technician.

Lamp replacement:

1. Disconnect the fixture from AC power and allow it to cool for 15 minutes.
2. Loosen the thumb screw (Figure 1) and lift the cover.
3. Remove the base of the old lamp from the socket.