piCOMPACT
Pin configuration for standard-IO
M12 8p
Pin No.
Name
1
V
sys
2
GND
3*
V1
4*
V2
5*
S1**
6*
S2**
7*
C1
8*
C2
*Different operating alternatives depending on your piCOMPACT
**S1 and S2 can deliver 2x40mA simultaneously or 1x80mA one at a time.
Bold text = Preset value (S2 offers different presets depending on configuration)
23 SMART 1 channel
®
Pin 3-8 can be configurated in the menu system to do other functions. See the
manual for your configuration on www.piab.com for more information.
Description
Supply voltage, 24 VDC (V+)
Common, 0 VDC (V-)
0 = Vacuum control
1 = Blow-Off control
2 = Disable Energy Saving (ES)
3 = Disable Automatic Blow-Off functions (ATBO or IBO)
4 = Disable Automatic Condition Monitoring (ACM)
5 = Process Data Out valid (PDO)
0 = Vacuum control
1 = Blow-Off control
2 = Disable Energy Saving (ES)
3 = Disable Automatic Blow-Off functions (ATBO or IBO)
4 = Disable Automatic Condition Monitoring (ACM)
5 = Process Data Out valid (PDO)
0 = No function
1 = Part Present vacuum level achieved (PP)
2 = Energy Saving vacuum level achieved (ES)
3 = Leakage Warning (LW)
4 = Blow-off Complete (BOC)
0 = No function
1 = Energy Saving vacuum level achieved (ES)
2 = Part Present vacuum level achieved (PP)
3 = Leakage Warning (LW)
4 = Blow-off Complete (BOC)
5 = Analog output, 1-5 VDC
Invert Interpretation of pump I/O, connect pin 7 to pin 2 to go
from: PNP -> NPN or NPN -> PNP.
Control function also configurable in pump menu system.
0 = No function
1 = Disable Energy Saving (ES)
2 = Disable Automatic Blow-Off functions (ATBO or IBO)
3 = Disable Automatic Condition Monitoring (ACM)
4 = Process Data Out valid (PDO)
23 SMART configuration.
®
Note
Digital input
Valve 1 control or C2
control functions
Digital input
Valve 2 control or C2
control functions
Digital output
Signal 1**
Digital output
Signal 2**
Digital input Control 1
Digital input
Control 1
11