About This Document; General Safety Precautions - STEINEL PROFESSIONAL IR 180 UNIVERSAL Manual Del Usuario

Ocultar thumbs Ver también para IR 180 UNIVERSAL:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
GB

1. About this document

Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or in part only with our
consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
Disconnect the power supply before
!
attempting any work on the unit�
• During installation, the electric power cable to be connected must not be
live. Therefore, switch off the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor involves work on the mains power supply. This work
must therefore be carried out professionally in accordance with national
wiring regulations and electrical operating conditions.
• Only use genuine replacement parts.
• Repairs must only be made by specialist workshops.
3� IR 180 UNIVERSAL
Proper use
– Sensor switch suitable for indoor wall-mounting.
– Intelligent sensor technology automatically switches any type of lamp ON
when the room is entered and OFF again after the preset time.
IR 180 UNIVERSAL
The infrared sensor switch IR 180 UNIVERSAL in a 2-wire design makes it pos-
sible. It can be installed with conventional 2-wire cables, making it a real sensa-
tion. The integrated SuperCap, which feeds the sensor switch in the event of a
power interruption, ensures perfect operation thanks to the zero-watt standby
mode consumption. This means it can switch every lamp on and off, making it
- 18 -
a future-proof investment. The IR 180 UNIVERSAL comes in a completely new
design and can be installed quickly and easily in all existing walls.
SuperCap charging behaviour
The integrated energy storage system is always charged when lighting is
switched ON. If lighting is switched OFF, the sensor operates on the energy
contained in the integrated storage system. In a room used for an average
period of time with lighting of average output and moderate stay-ON time, the
light's ON duration is sufficient to charge the energy storage system for the
remaining operating time.
In rooms used for very short periods of time with very low output lighting,
the IR 180 UNIVERSAL may not be able to store sufficient energy during ON
phases for the OFF phases. In such cases, the IR 180 UNIVERSAL will switch
lighting ON to charge the integrated energy storage systems even if no move-
ment is being detected.
If the energy storage system's state of charge is very low, lighting cannot be
switched OFF manually either in such instances until a minimum charge level
is reached. Otherwise there is a risk of the energy storage system discharging
completely, preventing the IR 180 from operating reliably.
Package contents (Fig� 3�1)
Product dimensions (Fig� 3�2)
Product components (Fig� 3�3)
A Rocker switch
B Cover
C Lens
D Removal slot
E Sensor module
F Surround
G Metal frame
H Load module
I
Manual reset (emergency start button)
4� Installation
• Switch OFF power supply (Fig� 4�1)
The mains connection terminal is designed for a maximum of 2 x 2.5 mm².
The mains power supply lead is a cable with at least 2 conductors:
L = phase conductor (usually black, brown or grey)
= switched phase conductor (usually black, brown or grey)
Note:
The mounting location should be at least 1 m away from any lights because
heat radiated from these may activate the system.
- 19 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

033149033132

Tabla de contenido