Backup receiver key number: 10, Enter. Same as for
Primary receiver key number.
Backup receiver encryption key: 11, Enter. Same as for
Primary receiver encryption key.
Backup alternative path test time: 12, Enter. Same as for
Primary alternative path test time.
Note:
For version firmware TDA74XX 1.13, set the
following additional settings using the TDA74XX
application or terminal, and USB connection between a
PC and the TDA74XX dialler:
- set Panel type = VdS with command: AT!U19=1
- set Report X25 status = Disabled with command:
AT!U20=0
USB connection between the dialler and a PC or other
device causes ISDN fault event. Use this connection only
during service.
Specifications
Power supply
Current consumption:
From panel
From battery
Ethernet standard
GSM/GPRS operating frequency
ranges
IRIS communication ports:
Remote Service App
Diagnostics
Polling
Alarm reporting
Dimensions
Weight
Operating temperature
Relative humidity
Dialler installation for LPS1277 compliant
applications
Background
The TDA74xx range of alarm over IP diallers is certified to be
compliant with the European standards for Intruder and Fire
Alarm transmissions and also to the additional requirements for
the UK specific standard LPS1277: Requirements for LPCB
Approval and Listing of Alarm Transmission Equipment.
For this LPS standard there are special instructions for the
installer, which are detailed in this document.
Requirements for the Monitoring Centre
For support of TDA74xx diallers at the supervised premises,
the monitoring centre must use TDA74xx Secure Apps alarm
receiving system.
Each dialler is given a 'template' that defines its operating
parameters such as reporting period. To ensure compliance
14 / 84
12 ±3 V
300 mA
370mA
IEEE 802.3
1710 to 1785 and 1805 to
1880 MHz, GSM 1800 (band I)
880 to 915 and 925 to 960 MHz,
GSM 900 Extended (band I)
TCP 10001
TCP 51292
TCP 52737
TCP 53165
80 x 90 x 22 mm
67 g
−10 to 55°C
95% max, noncondencing
with LPS1277, the following settings must be applied to these
templates:
'Enable auto security key'.
Peripheral connection 'Panel' if the connection between
the alarm system and the dialler is the 'dial capture
interface'.
Peripheral connection 'Pins' if the connection between the
alarm system and the dialler is the dialler 'pin' inputs.
Templates settings depend on the ATS performance
parameters required (ATS 1 to 6) and should be set as
maximum to the values shown in the table below.
ATS
A
B
1
24 h
50 min
2
24 h
50 min
3
24 h
50 min
4
4 h
50 min
4 plus
6 min
3 min
5
1 min
100 s
A
Poll period
B
Poll overdue margin
C
Ethernet reporting time (where dual path is used)
D
GPRS reporting time (where dual path is used)
E
Background checking interval (where dual path is used)
F
Background retry interval (where dual path is used)
Note:
If a faster polling period is required, e.g. to offer quicker
remote access, it is allowable to decrease the poll period (A)
and increase the poll overdue margin (B) as long as the sum of
the two is no higher than the sum of the two in the table above.
Installation guidance for LPCB approved
supervised premises transceivers (SPT)
connected to Intrusion & Hold up Alarm
Systems (I&HAS)
This 'Best Practice' guidance on installation practices will help
enhance general Alarm Transmission System (ATS) security/
resilience, avoid undue (false) path failure reports and reduce
customer inconvenience.
Important notes
1)
A claim to have installed LPCB approved SPT will be
invalid if this guidance has not been followed.
Within this guidance the word 'shall' indicates a mandatory
2)
requirement. Use of the word 'should' indicates a
requirement unless practical constraints prevent
compliance.
Installation (alarm company) Information
Location and alarm protection of the Supervised Premises
Transceiver (SPT)
i)
The SPT part of the Alarm Transmission Equipment
(ATE), shall be located within the I&HAS Control and
Indicating Equipment (CIE), or within an enclosure that
shares the same mains power supply, and has the same
level of battery back up and tamper protection, as is
required for the associated CIE.
P/N 1079518 (ML) • REV D • ISS 15OCT13
C
D
E
F
0 s
4 h
24 h
10 min
0 s
4 h
24 h
10 min
0 s
4 h
24 h
10 min
0 s
4 h
24 h
10 min
0 s
4 h
24 h
10 min
0 s
4 h
4 h
10 min