Maintenance

Function test

Recommendation: regularly perform the function test described
below.
Task
Check LED
.
Press the
<TEST>
button.
Press the
<TEST> button
for 1 second.
Maintenance
Have the maintenance work described below carried out every
2 years by a skilled person.
• Clean the basket filter.
• Clean and descale the trap.
18014401053566091-1 © 07-2018
967.986.00.0 (01)
Result
Control unit shows the
current operation
mode.
Solenoid valve opens
and water continues
to flow for the set
flush time.
Action
If LED
flashing, replace the
battery. → See
"Replacing the
battery", page 46.
Replace the battery
if no LED lights up.
→ See "Replacing
the battery",
page 46.
If water does not
flow → see
"Rectifying
malfunctions",
page 43.