4
USE
CAUTION:
For the implementation on already operating systems it is necessary to follow all safety
rules described herein. System assembly and start-up must be carried out by expert per-
sonnel according to the safety rules so as to ensure the same safety level of the system
the control box is going to be installed in.
Push up the switch (ON position) to open the relevant valve and start the delivery. The LED ON
indicates the switch is in spraying position (Fig. 4).
5
MAINTENANCE
In case of failure, check the fuse and the wiring (Fig. 2).
5.1
Troubleshooting
FAULT
The LEDs turn on but are
unable to control the relevant
valves
All LEDs are OFF and the
valves do not work
6
TECHNICAL DATA
Description
Power supply
Max. switching current per each output
Working temperature
Stocking temperature
Output protection through resettable fuse
Dimensions
Weight
7
DISPOSAL AT THE END OF SERVICE
Dispose of the system in compliance with the established legislation in the country of use.
CAUSE
Disconnected connectors
The internal protection is
active
Burnt fuse inside electric
circuit (Fig. 2)
Power supply failure
Control box for Seletron electric valves
12 Vdc (Vmin 9 / Vmax 16)
1,5 A
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
-20 °C ÷ 55 °C / -4 °F ÷ +131 °F
•
80 x 115 x 93 mm (harness excluded)
742 g (harness included)
• Connect the connectors.
• Cut-off the supply and wait for at least 20 seconds
before switching the control box on. If the problem
persists, please contact the nearest Assistance
Centre.
• Replace the fuse. If the problem persists, please
contact the nearest Assistance Centre.
• Check power supply.
7
REMEDY
Tab. 1