b) Lift the indoor unit, and place it on the washers
through the notches, in order to fix it in place.
(Fig. 3-46)
c) Tighten the 2 hexagonal nuts on each
suspension bolt to suspend the indoor unit as
shown in Fig. 3-47.
NOTE
The ceiling surface is not always level. Confirm that
the indoor unit is evenly suspended. For the installa-
tion to be correct, leave a clearance of about 10 mm
between the ceiling panel and the ceiling surface
and fill the gap with an appropriate insulation or filler
material.
(8) If the tubing and wiring are to go towards the rear
of the unit, make holes in the wall. (Fig. 3-48)
(9) Measure the thickness of the wall from the inside
to the outside and cut PVC pipe at a slight angle
to fit. Insert the PVC pipe in the wall. (Fig. 3-49)
DC̲Inverter̲Eng.indd 31
DC̲Inverter̲Eng.indd 31
Fig. 3-46
Fig. 3-47
NOTE
The hole should be made at a slight downward slant
to the outside.
Indoor
side
Fig. 3-48
PVC pipe (locally purchased)
Cut at slight angle
Fig. 3-49
31
Outdoor
side
INSIDE
OUTSIDE
Wall
PVC pipe
Slight
angle