10. After base driver assembly is in position, add (1)
washer, (1) lock washer, and (1) nut per anchor bolt and
torque bolts to 30 ft.-lbs. (41 N-M). (Figure 3.)
Figure 3.
11. Make wire connections, refer to wire diagram for power
connections. Connect the supply wires to appropriate
luminaire leads.
Supply side ground wire to green luminaire lead.
●
●
Supply side neutral wire to white luminaire lead.
●
●
Supply side line voltage wire to black luminaire lead.
●
●
12. Locate 2 pin polarized connector and ground wire on
driver assembly. Lift bottom open end of fixture and
position 2 pin connector and ground wire near top of
driver assembly. Assemble connector and connect
ground wires.
Installation Instructions - Arbor Bollard
13. Lift fixture and slide it over base driver assembly and
align bottom holes with base extrusion. (Figure 4.)
N
ote:
Ensure the LED and ground wires do not get
pinched between base driver assembly and
fixture housing.
14. Use (3) 1/4" socket cap flat head screws and tighten to
30 in-lbs. (3.4 N-M) with Allen wrench.
Figure 4.
EATON
IB501001EN
Installation instructions
3