PROGRAMMING STEPS
If the device that you wish to programme is a telephone, begin at step 3. If it is a monitor, begin at step 1.
In the case of a monitor: Connect the monitor cable strip in the connections bracket
In the case of a monitor: For greater ease, you can lean the monitor against the connections bracket. To do so, fit the upper right-hand tab
of the connections bracket into the central slot on the base of the monitor
Connect the cord between the telephone/monitor base and the receiver. You will hear a continuous tone with the PROG switch in the ON
position.
Turn the PROG switch to the OFF position (4.1), the tone stops. Turn the switch back to the ON position (4.2).
Press the lock release button. This will establish communication with the main entrance panel of the building. The telephone/monitor is ready
to receive the code.
From the main entrance panel, make a call to the dwelling where the telephone/connections bracket to be programmed is installed. The
screen of the entrance panel will show the device programming menu, enabling you to make the call either by using the electronic directory
or by directly keying in the code of the dwelling. The panel emits a confirmation tone. The connection bracket/telephone has been programed.
Note: Maximum time limit of 1 minute between Steps 4 and 5 and between 5 and 6. The system warns by means of a series of beeps of the
end of the time limit between Steps 5 and 6; repeat Step 5 to have another minute. If the time limit is exceeded the process must be repeated
from Step 4.
2 - W I R E
D O O R
E N T R Y