Other :
Automatic Closing :
The control unit allows you to close the window automatically
without sending additional commands.
The choice of the time is selectable thanks to the dedicated
SEAV "BeTech" application.
D.S. : Security Device ( Photocell ):
The control unit allows the power supply and connection of
photocells, pneumatic ribs (NC).
The intervention of the photocells in the opening phase is not
considered, in the closing phase causes the inversion of the
motion.
Warning: this input, if not used, must be bridged or
deactivated using the dedicated "BeTech" SEAV application.
FCAP – FCCH : opening & closing limit switch:
The control unit allows the connection of opening and closing
limit switch (NC). The intervention in the respective operating
phases
causes
the
immediate
Warning: these inputs, if not used, must be bridged or
deactivated using the dedicated "BeTech" SEAV application.
Operation with TIMER:
The control unit can have a timer set up instead of an open-
close control button.
Example: at 08:00 the timer closes the contact and the control
unit opens the gate. At 18:00 the timer opens the contact and
the control unit closes the gate. During the interval between
08:00 and 18:00, at the end of the opening phase, the control
unit disables the flashing beacon, automatic closing and radio
controls.
Settings :
The control panel is supplied by the manufacturer with the
possibility of selecting some important functions, using the
dedicated SEAV "BeTech" application.
CODE :
(Programming of the radio remote control)
The control unit can memorize up to 100 radio controls
with different codes like Fix, Rolling Code or Plus.
The transmission code must be programmed as follows:
press the CODE key of the "BeTech" SEAV application
via Smartphone, at the same time send the desired code
of the desired radio control; when the control panel will
issue a confirmation beep, the programming will be
completed. If all the 100 codes have been memorized,
repeating the programming operation, the control unit will
emit a long Beep signaling that no further memorization is
possible.
DELETE Remote Control:
The cancellation of all the memorized codes is carried out as
follows: press the DELETE key of the "BeTech" SEAV
application via Smartphone, at the same time the control unit
will emit a confirmation beep, preceded by messages visible on
the Smartphone.
Programming by Remote RCD :
The electronic control unit, using the dedicated SEAV "BeTech"
application via
Smartphone,
Programming function of a remote radio remote control by
means of a remote control already present in the memory: The
remote radio control programming is carried out as follows:
send in Continuous mode for a time greater than 10 seconds
the code of a previously memorized radio control, at the same
time the control unit enters programming mode as described
above in the CODE paragraph.
stop
of
the
motion.
allows you
to select
Flashing : (Flashing output operation)
The control panel has a 230Vac output for connecting a
flashing light or a courtesy light.
The electronic control unit, using the dedicated SEAV
"BeTech" application, allows the choice of the functioning
of the 230V Flashing output:
- Curtesy Light : Courtesy light active for 3 minutes
following an opening command.
- T. Mot. : Flashing active only during ON motors.
- T. Mot. + Automating Clos. Time : Flashing active
only during ON motors and during Automatic Closing
Time.
- T. Mot. + Pre-Flashing : Flashes 3 seconds before
starting the motors and during motors ON.
- T. Mot. + Pre-Flashing + Automating Clos. Time :
Flashes 3 seconds before starting the motors, during
ON.e motors and during Automatic Closing Time.
T. MOT : (Manual programming of engine work time.)
The control unit is supplied by the manufacturer with a
predefined motor working time of 30 seconds.
If a reprogramming of the motor working time is required, it
must be done with the Door closed as follows: press the T.
MOT. button for the SEAV "BeTech" application for a moment
using the Smartphone, the Door will start the ascent phase,
when the point is reached desired, press the T. MOT. button of
the application again, at the same time the motor time will be
memorized. It is advisable to memorize a time longer than a few
seconds after the window has reached the limit switch.
Follow Me :
The electronic control unit, using the dedicated SEAV "BeTech"
application via Smartphone, allows you to select the Follow Me
function: this function can only be programmed if a Pause Time
has already been programmed, and it is planned to reduce the
pause time to 5 sec. after disengaging the photocell, ie the
window closes 5 sec. after the user has passed.
Input Configuration :
The control panel is supplied by the manufacturer with the
possibility of Activate / Deactivate the inputs of the CN2
connector or change the functionality, using the dedicated
SEAV "BeTech" application.
Reset :
The control unit allows the control panel to be reset
to the factory configuration, by using the dedicated
SEAV "BeTech" application, press RESET at the
same time the control unit will emit a confirmation
beep.
Diagnostics :
The control unit allows monitoring in Real time, using the
dedicated SEAV "BeTech" application, the status of all the
the
INPUTS and OUTPUTs, the number of radio controls present in
the memory and of the type and other useful information for the
installer.
6
rev. 1.2 10/10/2019