5.6
Wiring connections
To connect the valve, use the cable with Tyco Superseal® 4-pole connector for CAN-BUS.
4
3
2
1
Connect the valve connector to that of the relevant harness; make sure it is correctly fitted and push
it until it locks in place (Fig. VII).
WARNING: CHECK THAT THE CONNECTOR IS FITTED CORRECTLY TO ENSURE A
PROPER SEALING.
WARNING: If the gasket is not positioned correctly, there may be infiltrations of water
in the connector and in the valve, with the consequent risk of damage to the device.
6
USE
6.1
Commands
The specifications of SAEJ1939 and A-Net protocols to send commands to the valve can be
requested by contacting the ARAG technical support department to the following address: support@
aragnet.com.
6.2
LED signals
A LED positioned on valve connector indicates the relevant status:
1
GND
2
+12 Vdc
3
CAN L
4
CAN H
Fig. IX
An intermittent flashing lasting 10 seconds indicates that the valve is
waiting to acquire a CAN-BUS address. After the aforementioned
GREEN BLINKING
period, the LED turns solid green, even if the address has not yet
been acquired.
GREEN STEADY
The valve is configured and functioning.
ON
A red flashing indicates a malfunction.
RED
An error code is identified according to the number of blinks
BLINKING
(refer to
Tab. 4
)
15