Additional information
1.
One side of the silicone rubber strip is located across the cover plane, and the other can be
used to install objects and print labels.
2.
During operation, press the emergency stop button to switch off the machine in an
emergency; the machine cover will open automatically.
3.
If the machine is not in use, the power (external common source) should be turned off.
4.
The cross-sectional area of the external power supply wire should be larger than that of
the internal power supply wire.
5.
If the place of machine operation is at a considerable altitude, the atmospheric pressure of
the environment will decline, and the rate of vacuum pressure gauge, respectively,
decrease (see the table).
Height (m)
0
200
400
600
800
1000
2000
3000
4000
6.
When operating over 10 hours per day or in the summer, you must make arrangements for
artificial cooling of the vacuum pump, removing it from the packer to maintain in
working condition.
Atmospheric pressure (mm Hg)
760
742.15
724.64
707.47
690.63
671.11
596.25
525.87
467.40
Vacuum degree (MPa)
0.101
0.099
0.097
0.094
0.092
0.090
0.079
0.070
0.062
EN
19