Descargar Imprimir esta página

Register Wireless Thermostat And Outdoor Sensor To The Controller - Uponor Smatrix Move PLUS Guía Rápida

Ocultar thumbs Ver también para Smatrix Move PLUS:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
Register wireless thermostat and
outdoor sensor to the controller
Caution!
The DIP switches in public thermostat
T-163 must be set before the thermostat is
registered.
N O T E !
If the outdoor sensor is placed to far
away from the reference room, a separate
thermostat can be used to register the
outdoor sensor.
N O T E !
If more than 4 hours have lapsed since
start up of the controller, a locked system
parameter symbol
is displayed when
entering the system parameters menu.
Restart the controller to unlock all system
parameters.
N O T E !
When registering a thermostat to the
controller, run mode changes parameter 0
(type) to rEv, regardless of previous setting.
Heating/cooling is then controlled by the
thermostat, or the integrated system.
To register a thermostat to the controller:
1. Press and hold the OK button on the controller for
about 10 seconds to enter the system parameters
menu.
2. The settings icon is displayed in the top left hand
corner of the display, and the text Hot type, Cld
type, or rEv type (depending of current operating
mode) is displayed.
Thermostat registration
3. Use buttons < or > to locate parameter 5 (th)
– Type of thermostat.
4. Use buttons - or + to change parameter settings to
rf.
5. Press the OK button on the controller to confi rm
the change and return to the system parameter
settings.
6. Use buttons < or > to locate parameter 8 (trF1)
– Wireless thermostat 1 confi guration.
7. Use buttons - or + to change parameter settings to
INI.
U P O N O R S M AT R I X M O V E P L U S · Q U I C K G U I D E
All manuals and user guides at all-guides.com
Q U I C K G U I D E
8. Thermostat T-166, T-167 and T-168
8.1 Press and hold the OK button on the
thermostat for about 5 seconds to enter the
settings menu. The settings icon and menu
numbers are displayed in the top right corner of
the display.
8.2 Use buttons - or + to change the numbers to 09
and press OK. The text Int no is displayed.
8.3. Use buttons - or + to change Int no to Int
CNF.
8.4. The connection indicator starts fl ashing in the
thermostat display to show that the registration
process begins.
8.5 The current reference room temperature is
shown in the controller display, and the text Int
YES is shown in the thermostat display when
the registration is complete.
8.6 Press and hold the OK button on the
thermostat for about 5 seconds to exit the
settings menu, or wait about 70 seconds for the
software to exit itself.
Thermostat T-163
8.1 Gently press and hold the registration button
on the thermostat, release when the LED starts
fl ashing green (located in the hole above the
registration button).
8.2 The current reference room temperature is
shown in the controller display when the
registration is complete. It might take some
time for the thermostat to send the current
temperature data to the controller. 00.0 is
displayed in the meantime.
9. Press the OK button on the controller to confi rm
the change and return to the system parameter
settings.
Wireless outdoor sensor registration
N O T E !
Skip to step 17, End registration, if the
outdoor sensor is wired to the controller.
10. Use buttons < or > to locate parameter 13 (OUSE)
– Outdoor sensor selection.
11. Use buttons - or + to change parameter settings to
rf.
12. Press the OK button on the controller to confi rm
the change and return to the system parameter
settings.
13. Use buttons < or > to locate parameter 15 (ourF)
– Wireless outdoor sensor confi guration.
14. Use buttons - or + to change parameter settings to
INI.
UK
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SK
1 1