Turbine recovery (water-operated) figure 32 or hydraulic/motor recovery figure 31.
Use (only for data display) of Metric or Imperial units of measurement. All machine settings must be
entered in metric units.
The last selection concerns the presence (figure 35) or absence (figure 37) of the modem for
sending/receiving alarm/control SMS messages and language selection (figure 36), each message also
has a unique code in case the desired language is not present. If the modem is enabled, the serial
status indication LED figure 9 starts flashing and can turn two different colours:
- flashing between green and red: it means that the display serial port is enabled, but does not
communicate with any device.
- flashing between green and blue: the serial port is enabled and the modem is in communication.
When the LED remains completely off it means that the display is not configured for communication
with the modem.
115
12.10.

Configuration completion.

The machine configuration is completed by setting the date and time and with the automatic restart of the
device. If everything was successful, the system restarts on the main page without any alarms and is ready
for operation.