14. Alarms.
Each alarm that blocks the machine appears on the main page in full screen and remains until the operator
acquires it. While all active alarms are displayed on the dedicated page accessible via the "Display alarms"
button figure 9.
The page shows all potential alarms, the active ones are marked with the number and flashing danger
triangle.
In this case the alarm 8 concerning SMS messages is active.
14.1.
Alarm list.
1- Battery alarm, low charge level.
a. Replace the battery.
2- I/O Module does not communicate with the Display.
a. Check correct insertion of the connectors (display and I/O module).
b. contact the support.
3- Litre counter sensor FAULT.
a. Check the electrical connection by referring to the diagram figure 1.
b. replace the device with an identical one.
4- Reference speed not reached.
a. Check the operating mode used.
b. Check the electrical connection of the sensor by referring to the diagram figure 1.
5- Minimum pressure alarm.
a. Check the actual presence of pressure on the machine pressure gauge.
b. Make sure the system configuration reflects the actual configuration of chapter 5.7.
c. Check the electrical connection by referring to the diagram figure 1.
d. Replace the pressure measurement device if required.
6-
7- Pressure transducer FAULT.
a. Check the electrical connection by referring to the diagram figure 1.
b. Replace the pressure transducer if required.
8- Alarm on SMS modem check details.
a. Check the type of alarm on the detail page chapter 7.2.
9- Chain slipping serious alarm.
a. Check the data entered in the anti-slipping system configuration chapter 5.4.
b. Check the actual efficiency of the mechanical system (the correct arrangement of the
chains).
c. Check the electrical connection of the inductive sensor by referring to the diagram figure 1.
10- Chain slipping indication, check the system.