Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

16.4.

Service.

F1
F2
F3
F4
Access to the page to save data from and to USB key F2, on this page it is possible to save
all the machine configuration data on any USB storage device (to be inserted in the USB port
on the back of the display), that can be loaded on another panel at a later stage.
Furthermore it is possible to download a logger file useful for diagnostics.
Access to the F3 ethernet network configuration page, it is currently possible to view the IP
address assigned to the system and select the operating mode of the ethernet port, for future
connections to devices such as routers.
By pressing and holding the F6 key for at least 5 seconds, the machine serial number entered
in the display is deleted (together with all consumption and hour counter data), after the time
required for deletion the display is restarted automatically.
By pressing and holding the F7 key for at least 5 seconds, all machine data goes back to the
factory configuration, ATTENTION the original data is not necessarily linked to the machine
mechanics, but is data consistent with the correct functioning of the display. In fact after the
procedure the system will be restarted and you will have to perform the complete
configuration since alarm N12 will be active.
SMART
20/01/2020
161
F5
F6
F7
F8
75

Publicidad

Tabla de contenido
loading

Tabla de contenido