Uso de generador – Requisitos de voltaje
Se deben considerar los siguientes requisitos cuando se
especifi que un generador para uso con este equipo:
• El calefactor requiere 120 voltios (Rango: 102 voltios a 132
voltios)
• El calefactor funciona a 60 Hz + 5% (Rango: 57 Hz a 63 Hz)
Communicating Enabled Furnace and Non-
Communicating Outdoor Unit
OPTIONAL
DISCHARGE
AIR SENSOR
COMMUNICATING
THERMOSTAT
CLIP ON-BOARD LINK
W915 (Y1 TO Y2) FOR
TWO-STAGE OPERATION
Outdoor Unit
COMMUNICATING FURNACE
OPTIONAL
OUTDOOR
AIR SENSOR
NON-COMMUNICATING
OUTDOOR AIR
CONDITIONING UNIT -
1 OR 2 STAGE
nace/air handler control and four wires between the outdoor unit and the furnace/air
handler control. When a thermostat cable with more than four wires is used, the extra
wires must be properly connected to avoid electrical noise. The wires must not be left
disconnected.
Use wire nuts to bundle the four unused wires at each end of the cable. A single wire
should then be connected to the indoor unit end of the wire bundle and attached to the
"C" terminals as shown below.
Communicating Integrated Control
• El control integrado del calefactor requiere polaridad correcta
y conexión a tierra apropiada. Se debe verifi car la polaridad
y la conexión a tierra apropiada antes de intentar operar el
calefactor con alimentación permanente o temporal.
• El generador debe tener una distorsión de forma de onda
de menos de 5% THD (distorsión armónica total).
Communicating Enabled Furnace and
Communicating Enabled Outdoor Unit
COMMUNICATING FURNACE
OPTIONAL
DISCHARGE
AIR SENSOR
OPTIONAL
OUTDOOR
AIR SENSOR
COMMUNICATING
THERMOSTAT
Figura 21
Página 21
DOOR AIR CONDITIONING
OR HEAT PUMP UNIT
Communicating Thermostat