Attaching Adapter Plate to Display using VESA 100 x 100
• Tighten screws so adapter brackets are fi rmly attached. Do not tighten with excessive force. Overtightening can
cause stress damage to screws, greatly reducing their holding power and possibly causing screw heads to become
detached. Tighten to 40 in. • lb (4.5 N.M.) maximum torque.
• If screws don't get three complete turns in the display inserts or if screws bottom out and bracket is still not tightly
secured, damage may occur to display or product may fail.
FOR VESA 100 x 100 MOUNTING PATTERN:
2
NOTE: Adapter plate (B) must be fully extended to access mounting holes.
Begin with the shortest length screw, hand thread through adapter
display. Screw must make at least three full turns into the mounting hole and fi t snug into place. Do not over
tighten. If screw cannot make three full turns into the display, select a longer length screw. Repeat for remaining
mounting holes and tighten screws.
NOTE: For displays with a hole pattern in a pocket, spacers (P or Q) go between adapter plate (B) and display.
SCREW
DISPLAY
B
WARNING
adapter plate and spacer in that order into
For displays with a hole
pattern in a pocket,
spacers (P,Q) go between
adapter plate (B) and
display.
6 of 38
ISSUED: 09-10-09 SHEET #: 202-9365-4 04-05-11