LUBRICATION
Ingersoll–Rand No. 50
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For USA – No. C28–04–FKG0–28
After each 20 000 cycles, or as experience indicates, drain
and refill the Impulse Unit Drive Assembly as instructed in
this manual using the Fluid Replacement Kit (Part
No. EQ106S–K400). Lubricate the hex drive and the output
shaft before assembly.
Model
Type of
Handle
100PQ1
pistol
PLACING TOOL IN SERVICE
Ingersoll–Rand No. 67
Ingersoll–Rand Fluid Part
No. EQ106S–400–1
SPECIFICATIONS
Chuck/Drive
in.
1/4" square dr.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
Free
Speed
rpm
9,300
4
FILTER
COMPRESSOR
(Dwg. TPD905–1)
Recommended Torque Range
Soft Draw
Hard Slam
ft–lb (Nm)
ft–lb (Nm)
3–6
3–8
(4–8)
(4–11)