1 INFORMATION ON THIS DOCUMENT
1.1 Function
The present operating instructions provide information on installation, connection and
safe use for the following articles: ST D••••••.
1.2 Target audience
The operations described in these operating instructions must be carried out by
qualified personnel only, who are fully capable of understanding them, and with the
technical qualifications required for operating the machines and plants in which the
safety devices are to be installed.
1.3 Application field
These operating instructions apply exclusively to the products listed in paragraph
Function, and their accessories.
1.4 Original instructions
The Italian language version is the original set of instructions for the device. Versions
provided in other languages are translations of the original instructions.
2 SYMBOLS USED
This symbol indicates any relevant additional information.
Attention: Any failure to observe this warning note can cause damage or mal-
function, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in these operating instructions is defined as a coded,
type-4 interlocking device without contact acc. to EN ISO 14119.
The safety sensors with RFID technology to which these operating instructions
refer are safety devices designed and implemented for the control of gates, guards,
enclosures, and doors in general, which are installed to protect dangerous parts of
machines without inertia.
3.2 Intended use of the device
- The device described in these operating instructions is designed to be applied on
industrial machines for state monitoring of movable guards.
- The direct sale of this device to the public is prohibited. Installation and use must be
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be
considered unintended by the manufacturer.
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications
to it;
b) using the product in a field of application other than as described in paragraph
TECHNICAL DATA.
4 INSTALLATION INSTRUCTIONS
Attention: Installing a protective device is not sufficient to ensure operator safety
or compliance with machine safety standards or directives. Before installing a protec-
tive device, perform a specific risk analysis in accordance with the key health and
safety requirements in the Machinery Directive. The manufacturer guarantees only the
safe functioning of the product to which these operating instructions refer, and not the
functional safety of the entire machine or entire plant.
4.1 Actuation directions
The device can be actuated by approaching the actuator from any direction.
The centring symbols
indicated on the device and actuator must face one
another when the guard is closed, regardless of actuation direction.
Article ST D••••••-D•T
Article ST D••••••-E•T
4.2 Selection of the actuator type
Attention: The device is available with two types of RFID actuator: with high
(articles SM •1T) or low (articles SM •0T) level of coding. If the chosen actuator has
a low level of coding, the additional specifications given in Std. EN ISO 14119:2013
paragraph 7.2 must be applied during the installation.
Attention: If the chosen actuator has a low level of coding, any other low level
coded actuators present in the same place where the device has been installed must
be segregated and kept under strict control in order to avoid any bypassing of the
safety device. If new low level coded actuators are fitted, the original low level coded
actuators must be disposed of or rendered inoperable.
It is advisable to use high coding level actuators to make the installation safer
and more flexible. In this way, no device screening, installation in inaccessible zones
or other requirements specified by the Std. EN ISO 14119 for low coding level actua-
tors will be necessary.
Article ST D••••••-L•T
Article ST D••••••-G•T
Pizzato Elettrica Srl
e-mail:
via Torino, 1
web site: www.pizzato.com
Phone:
36063 MAROSTICA (VI)
ITALY
4.3 Fixing of the device and actuator
fixed immovably to the door frame.
For correct fixing, other means can also be used, such as rivets, non-removable se-
curity screws (one-way), or other equivalent fixing system, provided that it can ensure
adequate fixing.
Tamperproof safety caps are provided with the device. Inserting the caps is
considered a suitable measure, to reduce the possibility of actuator disassembly to a
minimum, in accordance with EN ISO 14119. Therefore, by applying the caps supplied
to the device, normal screws can be used to affix the actuator.
Do not use a hammer for the adjustments, unscrew the screws and adjust the device
manually, then tighten it in position.
4.4 Assembly of multiple sensor-actuator systems
50 mm
4.5 Electrical connections of the device
4-pole versions
ST D•2••M•-••TV55
M12 connector
Connection
1
A1 (+)
2
OS1
3
A2 (-)
4
OS2
5-pole versions
ST D•2••••, ST D•6••••
M12 connector
Cable
1
brown
2
red/white
3
blue
4
black/white
5
black
/
red
8-pole versions
ST D•3••••, ST D•4••••, ST D•5••••, ST D•7••••, ST D•8••••
M12 connector
Cable
1
brown
2
red
3
blue
4
red/white
5
black
6
purple
7
black/white
8
purple/white
Legend:
A1-A2 = supply
IS1-IS2 = safety inputs
OS1-OS2 = safety outputs
4.6 RFID sensor switching points
When the actuator is brought inside the safe activation zone (dark grey area), the sen-
sor enables the safety outputs (OUT LED on, green).
When the actuator leaves the safe zone, the sensor keeps the safety outputs enabled
and, by means of the blinking LED ACT (orange), it indicates that the actuator is enter-
ing the limit activation zone (light grey area).
When the actuator leaves the limit activation zone, the sensor disables the outputs
(OUT LED off).
Attention: The device actuation/release distances can be influenced by the pres-
ence of conductive or magnetic material in the sensor vicinity. The working actuation
and release distances must always be checked following installation.
6/30
info@pizzato.com
ZE FOG124A21-EU
+39.0424.470.930
Attention: Always affix the sensor
and actuator with 2 M4 screws with re-
sistance class 4.6 or higher, and flat
seating heads. Install the screws with
medium resistance thread lock, and a
number of threads engaged equal to or
greater than the screw diameter. The de-
vice and actuator must never be fixed
with less than 2 screws. Tightening
torque of the M4 screws between 0.8
and 2.0 Nm.
Attention:
As
EN ISO 14119, the actuator must be
Where more than one safety device is in-
stalled to the same machine, the installa-
tion distance between sensor and actua-
tor systems must be at least 50 mm.
1
2
4
3
Connection
1
A1 (+)
OS1
A2 (-)
2
4
OS2
5
O3
(a)
3
not connected
Connection
1
7
A1 (+)
IS1
2
6
A2 (-)
OS1
3
5
4
8
O3
(a)
IS2
Notes
(a) inverted output for articles ST D•6••••,
OS2
ST D•7••••, ST D•8••••.
not connected
(b)
(b) for articles ST D•3••••, ST D•7••••.
I3
(c)
(c) for articles ST D•4••••, ST D•8••••.
EDM
(d) for articles ST D•5••••.
(d)
I3 = programming input
O3 = signalling output
EDM = monitoring input external contactors
required
by