align the body of the extension pumphead with the body of the first, fixed, pumphead. Fit the two
supplied extension pumphead fixing screws at each side of the extension pumphead and tighten.
Secure the cover plate to the extension pumphead using the two screws which secured it to the fixed
pumphead.
Position the tracks and secure them by closing the levers.
l
WARNING! Pumphead must only be operated with Track levers in
closed position.
8.3

Pump installation

For a correctly engineered installation please ensure that the following guidelines are followed:
Do not build a pump into a tight location without adequate airflow around the pump.
l
Do keep delivery and suction tubes as short and direct as possible and follow the straightest route.
l
Use bends of large radius: at least four times the tubing diameter. Ensure that connecting pipework
and fittings are suitably rated to handle the predicted pipeline pressure. Avoid pipe reducers and
lengths of smaller bore tubing than the pumphead section, particularly in pipelines on the suction
side. Any valves in the pipeline (not usually needed) must not restrict the flow. Any valves in the flow
line must be open when the pump is running.
Do use suction and delivery pipes equal to or larger than the bore of the tube in the pumphead.
l
When pumping viscous fluids use pipe runs with a bore several times larger than the pump tube.
Do ensure that your system fluid supply and discharge pipework is suitable for the hazardous
l
environment in which the pump is operating and doesn't allow for the accumulation of electrostatic
charge.
Do site the pump at or just below the level of the fluid to be pumped if possible. This will ensure
l
flooded suction and maximum pumping efficiency.
Do keep the pumphead track and all moving parts clean and free from contamination and debris.
l
Do run at slow speed when pumping viscous fluids. Flooded suction will enhance pumping
l
performance in all cases, particularly for materials of a viscous nature.
Do limit peristaltic tubing to the length adjacent to the pumphead because peristaltic tubing is
l
insulating. Electrostatic testing has been used to determine which Watson-Marlow tubing is suitable
for use in hazardous environments. See section 12 "Special conditions of use for safe operation -
Tube materials suitable for use with this equipment" on page 20 for more information. Earthed,
conductive pipework should be used elsewhere in the system.
When using Marprene or Bioprene continuous tubing, do re-tension the tube after the first 30
l
minutes of running.
If unsure of an installation please contact your local Watson- Marlow representative for further
l
assistance.
Tube selection: The chemical compatibility lists published in Watson- Marlow publications are
l
guides. If in doubt about the compatibility of a tube material and the duty fluid, request a Watson-
Marlow tube sample card for immersion trials.
16