ASSEMBLY
14.5

Power supply

When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1. The electronic connection of the machine is designated for operation with a grounded
power socket!
2. The mains supply must be secured with 16A:
3. If the connector plug doesn't fit or if it is defect, only qualified electricians may modify or
re-new it!
4. Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed
5. Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats
up.
6. A damaged cable must be replaced immediately
Operation is only allowed with safety switch against stray
current (RCD max. stray current of 30mA)
Use only permitted extension cable with cross-section
Voltage
220 V-240 V
50 Hz
HOLZMANN MASCHINEN GmbH
N O T I C E
NOTICE
the one in the following table declared.
Extension
<27 m
<44 m
<70 m
<105 m
www.holzmann-maschinen.at
A T T E N T I O N

Cross-section

1,5 mm
2
2,5 mm
2
4,0 mm
2
6,0 mm
2