Beretta EXCLUSIVE MIX C.S.I. Manual Para La Instalación Y El Uso página 24

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
MIX R.S.I.: programmable parameters
DESCRIPTION PARAMETERS
PAR.
1
GAS TYPE
2
BOILER POWER
3
INSULATION LEVEL OF BUILDING (+) (*)
10
DHW MODE
11
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
12
WATER TANK MAXIMUM SET-POINT
13
DELIVERY TERMPERATURE EXT. WATER TANK
14
DELTA EXTERNAL WATER TANK (ON)
20
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
21
HEATING CIRCUIT MAXIMUM SET-POINT
22
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
28
MAX HEATING POWER REDUCTION TIMER
29
FORCED HEATING SHUT DOWN TIMER
30
HEATING TIMER RESET FUNCTION
40
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
41
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
42
S.A.R.A. FUNCTION
43
S.A.R.A. BOOSTER FUNCTION
44
THERMOREGULATION FUNCTION
45
INCLINATION OF THERMOREG. CURVE (OTC) (*)
48
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
50
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
61
DHW ANTIFREEZE FUNCTION TEMPERATURE (ON)
62
HEATING ANTIFREEZE FUNC. DELIVERY TEMP. (ON)
85
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
86
THIS PARAMETER IS NOT USED ON THIS MODEL. DO NOT MODIFY
(*) parameters shown only with external sensor connected and parameter 44 in 1 (AUTO).
(+) for well-insulated buildings select values close to 20, for badly insulated buildings choose values close to 5.
Parameter 45 "Inclination of thermoregulation curve (OTC)"
The curve must be chosen according to the geographical area and the type of installation.
T m. - 20
OTC =
10 x
20 - T e.
UNIT OF
MEASURE
°C
° C
° C
° C
min
min
°C
°C
T m. = maximum rated temperature of heating water
T e. = minimum rated external temperature
MIN
-
1 Methane
2 LPG
3 Methane FR
-
26 (26kW)
30 (30kW)
34 (35kW)
-
5
0 (OFF)
1 (Istantaneous)
2 (Mini-tank)
3 (Ext. water tank with therm. - A and B case)
4 (Ext. water tank with sensor - C case)
40
50
0
45
0
0
-
0
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
0 (OFF)
1 (AUTO)
-
2,5
0
0
24
MAX
DEFAULT
(setted
in factory)
1-2
26-30-34
20
5
3
60
80
60
80
80
10
5
1
80
80
40
20
15
20
3
1
0
1
1
1
1
1
40
20
0
1
10
4
10
6
0
0.6
PARAMETERS
setted by techn.
assist. centre)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Exclusive mix r.s.i.

Tabla de contenido