43
3.2.1e - MODELS
25GE VAP / 45GE VAP / 46PE VAP / 61GE VAP / 64PE VAP / 101GE VAP / 104PEVAP
PROGRAMS (PHASE)
The oven must have the panel on with the temperature display
flashing (initial phase). Pressing the P button gives access to
programming and the corresponding display flashes, waiting
for data entry. Using the + and - buttons, choose the program.
To return to manual mode, press the + or - buttons to set MA
and confirm with P or wait for 15 seconds.
PROGRAMS
20 programs can be set by the user (from 1 to 20 inclusive) and
are displayed in numerical order. For each program, it is possible
to set 6 phases.
Entering a new program
Choosing the program number:
press the P button, the programs display flashes. Use the + or
- buttons to choose the program number to be stored or
changed. Wait 15 seconds for confirmation or press the P button.
Enter the program:
After choosing the program, hold down the P button to enter
the program itself. At this point, the data entry phase is the
same as for the manual program.
If the program is empty, the displays appear as they do in the
manual procedure, ready to receive data. If, on the other hand,
a program is already stored, the data entered is shown on the
corresponding displays. Data is entered as usual. If a further
phase is to be entered, press the F button. Use the + button to
choose the next phase then return to the usual data entry pro-
cedure. The same applies to all subsequent phases.
It is not necessary to enter all six phases in order to store a
program. To store a program, hold down the P button.
Temporary variation:
also in the programs cycle, by pressing the temperature, time
and humidity buttons, it is possible to vary the data entered
without modifying the original program stored.
pict. 19