Installation and Maintenance Instructions
5
5. Use the up or down arrows to correct the
water temperature as required.
6. After 5 seconds the correction is memorised
and the display stops flashing. The unit will
now operate as normal.
Proper disposal (electrical waste)
The labeling on the product and on the
accompanying literature declares that it must
not be disposed of, at the end of its service life,
with the ordinary household rubbish.
Common Problems and Solutions
Problem
The display does not
light up
The chiller does not bring
down the temperature of
the aquarium sufficiently
On the display appears
the message "AL"
On the display appears
the message "E1"
On the display appears
the message "E2"
The temperature
displayed is not the
temperature of the water
in the aquarium
Having checked the above you have been unable to resolve the problem, please contact your Arcadia retailer.
All manuals and user guides at all-guides.com
Cause
Solution
No electrical supply
Check that the electrical supply to the unit is connected at the wall and
at the chiller, that the switch at the electrical outlet (if applicable) is on
and that the power switch at the chiller is in the I (on) position
Check the fuse in the chiller plug and the circuit breaker or fuse at
your electrical distribution box
Blocked air filter
Clean the air filter as explained in 'Regular Maintenance'
Ambient temperature
Re-establish optimum ambient temperature conditions (the maximum
too high
ambient temperature for the chiller is 35°C)
Obstructed ventilation
Check that the ventilation panels in your cabinet have not become
clogged or obstructed
Damaged Fan
If one (or both) fans is not operating contact your Arcadia retailer
Dirty air filter
Clean the air filter following the instruction "Operation of cleaning"
Ambient temperature
Re-establish the optimal ambient conditions.
too high
(The maximum ambient temperature allowed is 35°C)
Obstructed ventilation panel
Clear the obstruction to the panel and if necessary relocate the chiller
Broken ventilation system
Contact a retailer
Damage of the water's
Contact a retailer
temperature probe
Damage of the
Contact a retailer
overheating probe
Water is not circulating
Check the hoses for obstructions and kinks
properly
Check that the pump is operating correctly
Hoses have insufficient
If hoses are particularly long they should be insulated and
insulation
reduced in length as much as possible
Water temperature display
Recalibrate the display (see below)
needs re-calibration
Please dispose of this equipment separately
from other waste, to protect the environment
and public health from damage by unregulated
waste disposal. Recycle the equipment and
support the sustained recycling of material
resources.
Users should contact their retailer or the
responsible civic authorities for advice on how
to recycle the equipment in an environmentally
friendly way.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

At650

Tabla de contenido