Final Checks And Start-Up; Barrier Type Selection; Choosing The Direction - Nice M-BAR Serie Instrucciones Y Advertencias Para La Instalación Y El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 149
ELECTRICAL CONNECTIONS
Terminals
Description
Input for devices that control the opening movement only; it is possible to connect "Normally Open" contacts.
OPEN
Input for devices that control the closing movement only; it is possible to connect "Normally Open" contacts.
CLOSE
input for devices that control the movement in the high-priority Step-by-Step mode and move the automation even
HP Sbs
if when it is in the stalled status; it is possible to connect "Normally Open"-type contacts.
input for connecting the radio receiver antenna; the antenna is incorporated in Nice LUCY B, MLB and MLBT
ANTENNA
warning lights.
Output used to connect the LED warning light board (XBA7) or the LED trafic light board (XBA8). Moreover, the
diagnostics lashes are carried out.
INTERNAL LIGHT
It can be programmed, refer to the "PROGRAMMING" chapter.
"Normally Open" contact to connect a metal detector D1.
The operating modes associated with this input can be modiied through the control unit programmer (refer to the
LOOP1
"Loop detector" paragraph).
"Normally Open" contact to connect a metal detector D2.
The operating modes associated with this input can be modiied through the control unit programmer (refer to the
LOOP2
"Loop detector" paragraph).
Input for connecting two barriers in Master-Slave mode (refer to the "Gearmotor in SLAVE mode" paragraph).
MASTER-SLAVE
"Normally Closed" contact for connecting the "Pivoting boom" contact (optional accessory).
SAFETY
a
If the programming of the outputs is modiied, check that the connected device matches the type of voltage
chosen.
5

FINAL CHECKS AND START-UP

5
FINAL CHECKS AND START-UP

5.1 BARRIER TYPE SELECTION

The controller has a set of dip-switches (A) in the OXI receiver
slot, allowing to identify the type of barrier. The dip-switches are
factory set: their meanings are given in the following table.
35
BARRIER TYPE SELECTION
Meaning of coniguration
Coniguration not
allowed
Installation M3BAR
Installation M5BAR
Installation M7BAR
Installation L9BAR
Coniguration not
allowed
66 – ENGLISH
A
Coniguration
Dip 1 Dip 2 Dip 3 Dip 4 Dip 5
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF

5.2 CHOOSING THE DIRECTION

Choose the direction of the opening manoeuvre on the basis of
the gearmotor's position.
Set the switching device as follows:
– set it to the RH if the spring is attached to the right-hand side
of the balancing lever (factory setting)
– set it to the LH if the spring is attached to the left-hand side of
the balancing lever
36
Table 5
OFF
OFF
OFF
OFF
OFF
OFF

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M3barM5barM7barL9bar

Tabla de contenido